Loading...
HomeMy WebLinkAbout1. PLN-20-00045 12510 Columbia WySTAFF REPORT PLANNING DIVISION DATE: AUGUST 19, 2020 TO: PLANNING COMMISSION SUBMITTED BY: ALDO E. SCHINDLER, DIRECTOR OF COMMUNITY DEVELOPMENT REVIEWED BY: CRYSTAL LANDAVAZO, CITY PLANNER PREPARED BY: IRVING ANAYA, ASSOCIATE PLANNER SUBJECT: PLN-20-00045 (CONDITIONAL USE PERMIT) – A REQUEST FOR A CONDITIONAL USE PERMIT TO ALLOW AN INDOOR SHRIMP FOOD PRODUCTION FACILITY WITH A SMALL RETAIL COMPONENT IN AN 18,140 SQUARE FOOT INDUSTRIAL BUILDING LOCATION: 12510 COLUMBIA WAY ZONING: C-M (COMMERCIAL MANUFACTURING) REPORT SUMMARY Stephen Sutton (hereinafter “the applicant”) is requesting a Conditional Use Permit (CUP) to allow an indoor shrimp food production facility with a small retail component in an 18,140 square foot industrial building located at 12510 Columbia Way. Pursuant to Downey Municipal Code (DMC) Section 9314.04, a food manufacturing (production) facility is permitted with the approval of a CUP in the C-M zone. Based on the analysis contained in this report, staff is recommending that the Planning Commission adopt the following titled resolution: A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF DOWNEY APPROVING PLN-20-00045 (CONDITIONAL USE PERMIT), THEREBY ALLOWING AN INDOOR SHRIMP FOOD PRODUCTION FACILITY WITH A SMALL RETAIL COMPONENT IN AN 18,140 SQUARE FOOT INDUSTRIAL BUILDING LOCATED AT 12510 COLUMBIA WAY, ZONED C-M (COMMERCIAL MANUFACTURING) BACKGROUND The subject site is improved with an industrial building located immediately south of the Columbia Memorial Space Center at 12510 Columbia Way. The site is zoned Commercial Manufacturing (C-M) and has a General Plan Land Use designation of Mixed Use (MU). The properties directly abutting from the east and south have a zoning designation of C-M. Properties to the north are within the SP 01-1 specific plan and properties to the west, across Columbia Way, are zoned Multiple-Family Residential (R-3) and Parking Buffer (P-B). PC Agenda Page 1 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 2 On May 6, 2020, the applicant submitted an application for a Conditional Use Permit requesting to operate an indoor shrimp food production facility with a retail component. Due to missing information, staff deemed the application incomplete on June 4, 2020. Upon further discussions with staff, the applicant submitted a revised request and project plans on August 3, 2020. Subsequently, on August 4, 2020, staff deemed the application complete for further processing. The notice of pending public hearing was published in the Downey Patriot and mailed to all property owners within 500’ of the subject site on August 6, 2020. DISCUSSION As previously stated, the subject site is improved with an 18,140 square foot industrial building. The subject site is approximately 42,708 square feet in size. As illustrated on the submitted site plan, the site is improved with 43 on-site parking spaces including two (2) ADA parking stalls. Uses surrounding the subject site include institutional/recreation to the north, manufacturing to the east, residential to the west, and storage sanitary services to the south. The proposed project is a request to convert an existing industrial building into a shrimp food production facility. The front of the building interior will contain a 275 square foot office, a 600 square foot retail space, and a 464 square foot storage/warehouse room. The remaining interior will contain an employee break room, restrooms, information technology (IT) room, wash-down area for the shrimp and a packing room. The bulk of the structure’s interior will be utilized to produce/grow shrimp in several large pools/tanks and house the equipment. The proposal will also include minor site improvements such as façade improvements including a new exterior paint scheme, new decorative wall lighting, landscape maintenance, and resurfacing of the front parking area. Additional improvements will include removal of an existing outdated chain link fence at the front of the property abutting the Columbia Memorial Space Center site and replacement of an existing gate with an enhanced iron gate used for the rear parking area. The facility will be staffed with up to 12 employees during the daytime hours, Monday through Sunday, 7:00 a.m. to 6:00 p.m. However, the facility will operate 24/7 because the tanks are required to run at all times to ensure proper growing conditions and appropriate life support for the shrimp within the building. The facility will be closely monitored remotely during closed hours using telemetry and cell phone alarms. The associated equipment and filters will be similar to those used in an aquarium. In addition to the food production and retail sales, the applicant is proposing to educate the public of all age groups on the science of indoor shrimp production through videos and special educational field trips to the subject site. With regards to parking, pursuant to DMC Section 9712, the parking requirements for each tenant space are as shown in Table No. 1 on the following page. PC Agenda Page 2 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 3 Table No. 1 Uses Within Building Square Footage Parking Calculation Parking Requirement Retail 600 1 per 250 S.F. of gross floor area 3 Office (includes add. rooms) 979 1 per 300 S.F. of gross floor area 4 Manufacturing/Warehousing 16,658 1 per 500 S.F. of gross floor area 34 Total 41 spaces Out of the existing 43 on-site parking spaces provided, the total required for the proposed business and specific uses within the building will be 41 parking spaces. As such, the site will have a surplus of 2 spaces, sufficient to accommodate all uses per the City’s parking standards. Upon review of the application materials, staff supports the request for a Conditional Use Permit to allow an indoor shrimp food production facility with a small retail component within an existing industrial building. DEVELOPMENT REVIEW COMMITTEE The project was reviewed by the Development Review Committee (DRC) and comments were provided. The Public Works Department provided conditions requiring the existing driveway entrance to comply with current City standards. Staff included conditions in order to address the department’s comments. Other departments had no other concerns and standard conditions were provided. ENVIRONMENTAL ANALYSIS Staff has reviewed the proposed use for compliance with the California Environmental Quality Act (CEQA). Upon completion of this review, it has been determined that this request is categorically exempt from CEQA, pursuant to Guideline Section No. 15301 (Class 1, Existing Facilities). Categorical Exemptions are projects, which have been determined not to have a significant effect on the environment and have been exempted from the requirements of CEQA. Class 1 consists of projects that involve interior alterations or exterior alterations to an existing structure. FINDINGS Pursuant to the requirements of DMC Section 9824.06 (Conditional Use Permit), staff recommends that the Planning Commission make the following findings to approve the overall request: 1.That the requested Conditional Use Permit will not adversely affect the intent and purpose of Article IX or the City’s General Plan or the public convenience or general welfare of persons residing or working in the neighborhood thereof. The requested Conditional Use Permit for the indoor shrimp food production facility will not adversely affect the purpose and intent of the DMC. The subject property is located within the C-M zone, which is intended to provide a flexible range of commercial, PC Agenda Page 3 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 4 wholesale, and light manufacturing uses that can be operated in harmony with each other and in a clean and orderly manner. The areas designated for the commercial and manufacturing zone are suitable for both types of uses in combination with each other or individually. The requested CUP will allow the production and sale of shrimp to local and regional areas. The C-M zone allows food product manufacturing with the approval of CUP. Approval of this CUP will allow the production of food such as the proposed shrimp in addition to the ancillary retail use permitted in the C-M zone. The proposed use also complies with Policy 1.1.4 of the City’s General Plan, wherein it states that the City of Downey should provide an appropriate amount of land area for people to acquire goods and services. 2.That the requested use will not adversely affect the adjoining land uses and the growth and development of the area in which it is proposed to be located. The requested Conditional Use Permit will not adversely affect the adjoining land uses since the use will be completely within an existing industrial building and adjacent properties operate manufacturing and storage uses with the exception of the northern and western properties. However, these northern and western adjacent sites contain structures that are situated 150 to 300 feet away from the proposed use. In addition, staff believes that the conditions included in the Resolution adequately ensure that the new use will not adversely affect the adjoining lots. Furthermore, the proposed use will undergo regulations enforced by other agencies such as the California Department of Fish and Wildlife, Food and Drug Branch of California Department of Health, and any other applicable agencies. 3.That the size and shape of the site proposed for the use is adequate to allow the full development of the proposed use in a manner not detrimental to the particular area. The size and shape of the site proposed for the use is adequate to allow the full development of the proposed use in a manner not detrimental to the particular area. The subject site is approximately 42,708 square feet in size. The existing structure will maintain its existing footprint at 18,140 square feet and the proposed use will occupy the interior of the building. Also, the site currently provides existing parking with a total of 43 on-site parking spaces where the use requires a total of 41 spaces. Lastly, Conditions of Approval have been included that would address the operation requirements, noise, odor, and trash. Therefore, the new use will not be an adverse impact to the area. 4.That the traffic generated by the proposed use will not impose an undue burden upon the streets and highways in the area. The traffic generated by the proposed use is not expected to significantly increase with the approval of the CUP, as the site currently accommodates sufficient on-site parking spaces. In addition, the applicant will be utilizing and only allowing pickup trucks and/or small vans for shipping purposes. Lastly, as previously stated in the report, the proposed use/business is not expected to have more than 12 employees on-site, thus providing a surplus of available parking spaces to the public and distribution vehicles and the site is adequately served by surrounding streets and highways. PC Agenda Page 4 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 5 CORRESPONDENCE As of the date that this report was printed, staff has not received any correspondence regarding this matter. CONCLUSION Based on the analysis contained in this report, staff recommends that the Planning Commission adopt the resolution approving the Conditional Use Permit (PLN-20-00045), subject to the conditions of approval as stated in the Planning Commission Resolution. EXHIBITS A. Aerial Photograph, Location Map & Zoning Map B. Draft Resolution C. Project Plans & Business Narrative PC Agenda Page 5 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 6 Exhibit ‘A’ – Maps AERIAL PHOTOGRAPH Subject Site Imperial Highway Co l u m b i a W a y PC Agenda Page 6 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 7 LOCATION MAP PC Agenda Page 7 12510 Columbia Way – PLN-20-00045 August 19, 2020 – Page 8 ZONING MAP Subject Property Imperial Hwy Co l u m b i a W a y R-3 PC Agenda Page 8 RESOLUTION NO. 20-_____ A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF DOWNEY APPROVING PLN-20-00045 (CONDITIONAL USE PERMIT), THEREBY ALLOWING AN INDOOR SHRIMP FOOD PRODUCTION FACILITY WITH A SMALL RETAIL COMPONENT IN AN 18,140 SQUARE FOOT INDUSTRIAL BUILDING LOCATED AT 12510 COLUMBIA WAY, ZONED C-M (COMMERCIAL MANUFACTURING) THE PLANNING COMMISSION OF THE CITY OF DOWNEY DOES RESOLVE AS FOLLOWS: SECTION 1. The Planning Commission of the City of Downey does hereby find, determine and declare that: A. An application was filed by Stephen Sutton (hereinafter referred to as the “the applicant”) on May 6, 2020 requesting approval of a Conditional Use Permit (PLN-20-00045) to allow an indoor shrimp food production facility with a small retail component in an 18,140 square foot industrial building; B. Staff deemed the application incomplete on June 4, 2020, due to staff concerns and missing information. Upon further discussions with the applicant, revised proposal and revised plans were submitted. Subsequently, staff deemed the application complete on August 4, 2020; and C. On August 6, 2020, notice of the pending public hearing was sent to all Downey property owners within 500 feet of the subject site and the notice was published in the Downey Patriot; D. The Planning Commission held a duly noticed public hearing on August 19, 2020 and after fully considering all oral and written testimony, facts, and opinions offered at the aforesaid public hearing adopted this resolution. SECTION 2. The Planning Commission further finds, determines and declares the environmental impact of the proposed development has been reviewed and has been found to be in compliance with the California Environmental Quality Act (CEQA) and is categorically exempt from CEQA, pursuant to Guideline Section No. 15301 (Class 1), Existing Facilities because the proposed use will involve interior and exterior alterations to an existing structure. SECTION 3. Having considered all of the oral and written evidence presented to it at said public hearing regarding the Conditional Use Permit, the Planning Commission further finds, determines and declares that: A. The requested Conditional Use Permit for the indoor shrimp food production facility will not adversely affect the purpose and intent of the Downey Municipal Code. Specifically, the subject property is located within the C-M zone, which is intended to provide a flexible range of commercial, wholesale, and light manufacturing uses that can be operated in harmony with each other and in a clean and orderly manner. The areas designated for the commercial and manufacturing zone are suitable for both types of uses in combination with each other or individually. The requested CUP will allow the production and sale of shrimp to local and regional areas. The C-M zone allows food product manufacturing with the approval of CUP. Approval of this CUP will allow the production of food such as the proposed shrimp in addition to the ancillary retail use permitted in the C-M zone. The proposed use also complies with Policy 1.1.4 of the City’s General Plan, wherein it states that the City of Downey PC Agenda Page 9 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 2 should provide an appropriate amount of land area for people to acquire goods and services. B. The requested Conditional Use Permit will not adversely affect the adjoining land uses since the use will be completely within an existing industrial building and adjacent properties operate manufacturing and storage uses with the exception of the northern and western properties. However, these northern and western adjacent sites contain structures that are situated 150 to 300 feet away from the proposed use. In addition, the conditions included in the Resolution adequately ensure that the new use will not adversely affect the adjoining lots. Furthermore, the proposed use will undergo regulations enforced by other agencies such as the California Department of Fish and Wildlife, Food and Drug Branch of California Department of Health, and any other applicable agencies. C. The size and shape of the site proposed for the use is adequate to allow the full development of the proposed use in a manner not detrimental to the particular area. The subject site is approximately 42,708 square feet in size. The existing structure will maintain its existing footprint at 18,140 square feet and the proposed use will occupy the interior of the building. Also, the site currently provides existing parking with a total of 43 on-site parking spaces where the use requires a total of 41 spaces. Lastly, Conditions of Approval have been included that would address the operation requirements, noise, odor, and trash. Therefore, the new use will not be an adverse impact to the area. D. The traffic generated by the proposed use is not expected to significantly increase with the approval of the CUP, as the site currently accommodates sufficient on-site parking spaces. In addition, the applicant will be utilizing and only allowing pickup trucks and/or small vans for shipping purposes. Lastly, as previously stated in the report, the proposed use/business is not expected to have more than 12 employees on-site, thus providing a surplus of available parking spaces to the public and distribution vehicles and the site is adequately served by surrounding streets and highways. SECTION 4. Based upon the findings set forth in Sections 1 through 3 of this Resolution, the Planning Commission of the City of Downey hereby approves this Conditional Use Permit (PLN-20-00045) subject to the Conditions of Approval attached hereto as Exhibit A, which are necessary to preserve the health, safety and general welfare of the community and enable the Planning Commission to make the findings set forth in the previous sections. The conditions are fair and reasonable for the accomplishment of these purposes. PC Agenda Page 10 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 3 SECTION 5. The Secretary shall certify the adoption of this Resolution. PASSED, APPROVED AND ADOPTED this 19th day of August 2020. Miguel Duarte, Chairman Planning Commission I HEREBY CERTIFY that the foregoing is a true copy of a Resolution adopted by the Planning Commission of the City of Downey at a regular meeting thereof held on the 19th day of August 2020, by the following vote, to wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: __________________________________ Mary Cavanagh, Secretary Planning Commission PC Agenda Page 11 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 4 CONDITIONS OF APPROVAL CONDITIONAL USE PERMIT (PLN-20-00045) PLANNING 1) The approval of this Conditional Use Permit allows the establishment of an indoor shrimp food production facility with a small retail component within an existing 18,140 square foot industrial building and façade and site improvements in accordance with plans submitted and filed under Case No. PLN-20-00045. 2) Approval of this Conditional Use Permit shall not be construed to mean any waiver of applicable and appropriate zoning regulations, or any Federal, State, County, and City laws and regulations. Unless otherwise expressly specified, all other requirements of the City of Downey Municipal Code shall apply. 3) The City Planner is authorized to make minor modifications to the approved preliminary plans or any of the conditions if such modifications shall achieve substantially the same results as would strict compliance with said plans and conditions. 4) All conditions of approval set forth in this Resolution shall be complied with before the Conditional Use Permit becomes valid. 5) The use approved herein must be executed within one year of approval or shall be subject to revocation where this approval will be deemed null and void. 6) The Planning Commission reserves the right to revoke or modify this approval if the proposed use becomes a public nuisance, finds the permit was obtained by fraud, the approved use is not being exercised, the approved use is operated in violation of the terms and conditions contained herein, or the approved use ceased or was suspended for one year or more. 7) The Owner/Applicant agrees, as a condition of approval of this resolution, to indemnify, defend and hold harmless, at Applicant's expense, City and City's agents, officers and employees from and against any claim, action or proceeding commenced within the time period provided in Government Code Section 66499.37 to attack, review, set aside, void or annul the approval of this resolution, to challenge the determination made by City under the California Environmental Quality Act or to challenge the reasonableness, legality or validity of any condition attached hereto. City shall promptly notify Applicant of any such claim, action or proceeding to which City receives notice, and City will cooperate fully with Applicant in the defense thereof. Applicant shall reimburse the City for any court costs and attorney's fees that the City may be required to pay as a result of any such claim, action or proceeding. City may, in its sole discretion, participate in the defense of any such claim, action or proceeding, but such participation shall not relieve Applicant of the obligations of this condition. 8) The permitted hours of operation of the business are Monday through Sunday from 7:00 a.m. to 6:00 p.m. 9) All installed exterior lighting shall be subject to a final inspection by the Planning Department. The illumination of the outdoor lights shall be adjusted to the satisfactory standard of the City Planner in order to provide appropriate on-site illumination and prevent spill over on to adjacent properties and the public right-of-way. PC Agenda Page 12 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 5 10) All signage shall be reviewed for a separate permit and must comply with the Downey Municipal Code, Chapter 6 (Signs). 11) All operations shall occur within the building. No outdoor uses shall be allowed. 12) Noise levels shall not exceed applicable noise standards specified in Downey Municipal Code Article IV, Section 4600 (Noises). 13) All new rooftop mechanical equipment shall be fully screened from public view. Said screening must be architecturally compatible with the building in terms of theme, materials, colors and textures. Any proposed screening shall be submitted for approval by the City Planner prior to the issuance of a building permit. 14) All new and existing landscape shall be maintained in a clean and neat manner to the satisfaction of the City Planner. 15) The proposed trash enclosure shall be constructed in accordance to Downey Municipal Code Section 9528 (Solid Waste) and the City’s Public Works Department standards. 16) Trash shall be collected as frequently as a daily basis to ensure that there are no odors or nuisance due to the nature of the use. 17) All trash and refuse containers shall be fully screened from public view. 18) The applicant shall implement an environmental control system that is adequately compatible with any odor control prevention and ventilation systems at the site. For purposes of this condition, “adequately compatible” means that any environmental control systems and odor control systems operating at the site operate concurrently to prevent odors from being detected outside the site, while still allowing the applicant to successfully produce shrimp to the satisfaction of applicable construction codes and the City Planner. 19) Prior to a Certificate of Occupancy, the City Planner shall conduct a final inspection of the site. 20) All applicable State and Federal Licenses and reviews for the proposed use shall be required to be approved prior to issuance of Certificate of Occupancy. BUILDING 21) All construction shall comply with the most recent adopted City and State building codes: 2019 California Building Code 2019 California Electrical Code 2019 California Mechanical Code 2019 California Plumbing Code 2019 California Fire Code 2019 California Green Code 22) Special Inspections – As indicated by California Building Code Section 1704, the owner shall employ one or more special inspectors who shall provide special inspections when PC Agenda Page 13 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 6 required by CBC section 1704. Please contact the Building Division at time of plan submittal to obtain application for special inspections. 23) The Title Sheet of the plans shall include: Occupancy Group Occupant Load Description of use Type of Construction Height of Building Floor area of building(s) and/or occupancy group(s) 24) Dimensioned building setbacks and property lines, street centerlines and between buildings or other structures shall be designed on plot plan. 25) All property lines and easements must be shown on plot plan. A statement that such lines and easements are shown is required. 26) The project design will conform with energy conservation measures articulated in Title 24 of the California Code of Regulations and address measures to reduce energy consumption such as flow restrictors for toilets, low consumptions light fixtures, and insulation and shall use to the extent feasible draught landscaping. 27) A design professional will be required at time of construction drawings, to prepare plans for proposed improvements per the Business and Professions’ Code. 28) Public and private site improvements shall be designed in accordance with the Americans with Disabilities Act and Chapter 11 of the California Building Code. Site plan shall include a site accessibility plan identifying exterior routes of travel and detailing running slope, cross slope, width, pedestrian ramp, curb ramps, handrails, signage and truncated domes. Path of travel shall be provided from the public right of way and accessible parking to building. The design professional shall ensure that the site accessibility plan is compliance with the latest Federal and State regulations. 29) All projects including food service or Public pools and/or spas shall be checked and approved by the LA County Health Department as part of the building department plan review process. PUBLIC WORKS 30) All public utilities shall be installed underground. 31) Proposed public improvements shall comply with the latest edition of Standard Plans and Specifications for Public Works Construction, City of Downey standards and the Americans with Disabilities Act (ADA). 32) Obtain permits from the Public Works Department for all improvements within the public right of way at least two weeks prior to commencing work. 33) Remove and replace sub-standard driveway approach per the satisfaction of the Public Works Department. Contact the Public Works Inspector at (562) 904-7110 to identify the limits of the areas to be removed and replaced at least 48 hours prior to commencing work. PC Agenda Page 14 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 7 34) Public improvement plan(s) shall be submitted for review and approval by Public Works Department. 35) Reconstruct existing driveway approach at least five (5) feet away from any above- ground obstructions in the public right-of-way to the top of the driveway “X.” Ensure that the driveway provides proper pedestrian access across, in compliance with ADA standards. The final layout and site driveway design shall be subject to the review and approval by the Public Works Department. 36) Remove all Underground Service Alert (USA) temporary pavement markings immediately following the completion of the work / Final permit inspection. 37) Any utilities that are in conflict with the development shall be relocated at the owner/applicant's expense. 38) Any acquired property in the form of easement, fee simple or irrevocable offer shall be in form acceptable by the city engineer and the city attorney prior to its recordation. 39) Owner/applicant shall coordinate with the County Sanitation District of Los Angeles to determine whether the property needs to apply for an Industrial Waste Discharge Permit. If so, owner applicant shall submit the permit application and supporting documents to the Public Works Department for them to review and forward to the County Sanitation District of Los Angeles. Prior to final sign off owner/applicant needs to have already obtain the permit from the county or a letter of exempt from the county regarding the Industrial Waste Discharge permit. 40) Owner or tenant must establish accounts with the City Cashier prior to the City activating and the tenant using any fire and potable water service and meter. 41) The owner/applicant shall provide separate water improvement plan sets for review and approval should there be any utility work in the public right-of-way. The plan shall consist of the following: a) Potable Water Improvement Plans (all City-owned potable water and fire service lateral improvements). b) Final City approved potable water and recycled water main improvement plans shall be submitted on mylars and shall be signed and stamped by a State of California licensed civil engineer. In addition to review and approval by City, recycled water main improvement plans shall be submitted to, and plan approval letter obtained from, the State Water Resources Control Board – Division of Drinking Water. c) Final City approved recycled water irrigation plans shall be submitted on mylars and shall be signed and stamped by a State of California licensed landscape architect. In addition to review and approval by City, recycled water irrigation plans shall be submitted to, and plan approval letter obtained from, LA County Department of Public Health. d) Improvement plans for potable water main improvements shall be both plan and profile. 42) Upon completion of water improvements, owner/applicant shall submit red-lined construction plans to City noting all changes to the plan and profile of all water PC Agenda Page 15 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 8 improvements installed. Such changes shall be incorporated into a final record drawing mylar which shall be signed and stamped by the original engineer and/or architect of record and submitted to the City along with digital files (AutoCAD – latest edition). 43) The water mains shall be of sufficient size to accommodate the total domestic and fire flow required for the property. The domestic/fire water flows required are to be checked and approved by the Dept. of Public Works or the water provider for size and velocity. Fire flows required are to be determined by the Fire Chief. 44) Any deviation from the city standards in constructing the water and sewer lines shall be approved by the Los Angeles County Health Department. 45) The owner/applicant shall comply with the National Pollutant Discharge Elimination System (NPDES); Ordinance 1142 of the Downey Municipal Code (DMC); and the Low Impact Development (LID) Plan. Furthermore, the applicant shall be required to Certify and append Public Works standard “Attachment A” to all construction and grading plans as required by the LACoDPW Stormwater Quality Management Plan (SQMP). 46) If any hazardous material is encountered on the site that has the potential to reach the ground water supply, the owner/applicant shall secure a permit for the State Regional Water Quality Control Board. 47) If any hazardous material is encountered on the site, the owner/applicant shall secure an ID number from the EPA. 48) The owner/applicant shall deploy Best Management Practices during and after construction. 49) The facility must provide for recycling facilities, i.e., storage and handling areas for recycling facilities. Trash enclosure shall include roof cover. 50) Complete a construction & demolition (C&D) waste management plan per Article V, Chapter 8 of the Downey Municipal Code. 51) Construct onsite pavement, consisting of a minimum section of 4” thick aggregate base, and a minimum 2-1/2” thick asphalt concrete pavement. Construct Pavement on-site parking and circulation areas as required by a pavement engineering or geotechnical report prepared by a Registered Civil Engineer, subject to the review and approval of the Public Works and Community Development Departments. 52) The owner/applicant must comply with all applicable Federal, State and local rules and regulations, American Disabilities Act (ADA), including compliance with South Coast Air Quality Management District (SCAQMD) regulations. FIRE 53) The establishment shall comply with all current code requirements for the occupancy use and type. 54) Premises shall be appropriately addressed. An approved address identification shall be provided that is legible and placed in a position that is visible from the street/road. Sizing shall be approved and at a minimum meet requirement of CA Fire Code [CA Fire Code PC Agenda Page 16 Resolution No. 20-_____ Downey Planning Commission 12510 Columbia Way - PLN-20-00045 August 19, 2020 - Page 9 §505.1] 55) Install approved key boxes (e.g. Knox Boxes) to occupancy [CA Fire Code §506.1]. 56) Automatic fire sprinkler system shall be maintained in operative condition at all times. The automatic fire sprinkler system shall have a current Title 19/NFPA 25 5-year inspection and testing with backflush of FDC witnessed by Downey Fire. All required inspection reports shall be submitted to Downey Fire [CA Fire Code §901.6; §901.6.3; CCR Title 19, Division 1, §904(a)(1)]. 57) Fire detection and notification system (e.g. fire alarm) shall be maintained in operative conditions at all times and undergo its required annual inspection and testing. Inspection and testing reports shall be submitted to Downey Fire [CA Fire Code §901.6; §901.6.3; NFPA 72 §14.3.1]. 58) If modifications are required to the existing automatic fire sprinkler or alarm systems, a licensed fire protection contractor (e.g. C-16, C-10) shall submit plans and obtain the required permit(s) from Downey Fire for said work. Work shall be subject to witnessed acceptance testing by this agency [CA Fire Code §105.7.1; §105.7.7; §901.5; NFPA 72 §14.4.2]. 59) Installation of Liquid Oxygen tanks and ozone generator shall require separate fire permits. A construction permit is required for installation of stationary cryogenic fluid storage systems [CA Fire Code §105.7.5] and hazardous materials systems [CA Fire Code §105.7.13]. 60) Establishment of hazardous materials business plan (HMBP) shall be required for the handling of reportable quantities of hazardous substances (e.g. Liquid Oxygen, etc.) [HSC 25507(5)(C)]. 61) If the handling of Ozone, a regulated substance, exceeds the Threshold Quantity of 100 pounds, the operator shall develop and submit a Risk Management Plan (RMP) in conjunction with the California Accidental Release Plan (CalARP) [19 CCR 4.5 §2735.5(b)(1), §2745.1(a)]. The operator shall closely coordinate implementation of the CalARP requirements with the Downey Fire Department [19 CCR 4.5 §2735.5(a)]. 62) Where deemed necessary by the Downey Fire Department, equipment cut sheets shall be provided. 63) If applicable for storage of hazardous materials, provide a visible NFPA 704 hazard warning placard to address side of building. NFPA 704 placard shall be required where hazardous substances equal to or above permitted quantities are handled, stored, or used [CA Fire Code §5003.5]. 64) Exit signs shall be properly illuminated and readily visible from any direction of egress travel [CA Fire Code §1013.1; 1013.31030.2; 1030.3]. 65) Egress shall be designed to meet requirements of CA Building Code and Chapter 10 of the CA Fire Code for occupant load, number of egresses, egress sizing, door swing direction, etc. END OF CONDITIONS PC Agenda Page 17 TransparentSea LLC Office: 4464 Le Park Dr. Long Beach, CA 90807 Steve@transparentseafarm.com (518) 764-0359 www.transparentseafarm.com Overview At TransparentSea, we promote safe and responsible indoor cultivation techniques that provide healthy environments for shrimp to thrive. We then utilize a series of filters to recycle the water and transform wastes into valuable organic fertilizers. Unlike the majority of farming in the world, we operate a closed system, managing everything that goes in and comes out of the process, instead of polluting our environment or waterways. We will use visually differentiated shrimp and decades of knowledge to educate consumers about clean aquaculture and fishing methods, thereby enabling them to purchase seafood with confidence. The TransparentSea brand fulfills our ultimate mission to relieve the pressure that our growing hunger for seafood has placed on the natural environment, while feeding our families with safe, local seafood well into the future. System TransparentSea Farm will be producing natural products (shrimp and seaweed) in a scientific setting, similar to an aquarium but focused on production for harvest and human consumption. Our inputs and outputs will be natural and not hazardous. There are no synthetic chemicals, antibiotics, pesticides or other elements to be added or discharged. Our brand and business model is built around resource efficiency and transparency. We are financially and ethically incentivized to use less water and to produce less waste now and into the future. The bulk of our equipment cost is dedicated to physical and biological filtration, sterilization, and the conveyance of water with the ability to re-use it for at least 300 days. When we design our systems, we focus on minimization of wastewater and expect to become even more efficient as we grow. This technology is not experimental, and our Chief Technology Officer has deployed it elsewhere with a successful water recycling rate of nearly 100%. Regulatory The following agencies will be involved in regulation/oversight:  California Department of Fish and Wildlife: Aquaculture Permit  Food and Drug Branch of California Department of Health  FDA: (A HACCP plan will be voluntarily and proactively developed, though we are producing/manufacturing and not ‘processing’ seafood).  Local City and/or County Jurisdictions for Fire, Building, Health, Utilities.  Business License and Sellers permit. Operational Information The core of our business is light industrial/manufacturing use, with life support systems quietly running 24/7. These include quiet, efficient water pumps, filters, and sterilizers. The facility will be staffed with 1-3 employees during daytime hours, PC Agenda Page 18 TransparentSea LLC Office: 4464 Le Park Dr. Long Beach, CA 90807 Steve@transparentseafarm.com (518) 764-0359 www.transparentseafarm.com approximately 7am-6pm, and at night will be monitored remotely using telemetry and cell phone alarms. Our facility will run quietly, involves no regular trucking larger than vans, and produces no smells that could affect the neighbors. Sales Avenues Approximately 1,000 pounds of shrimp will be sold each week through area farmer’s markets and directly to a handful of Los Angeles area restaurants. Our facility will include an FDA-compliant harvesting and packaging room, and shipping will occur with pickup trucks or small vans. This facility will employ 3-4 employees focused on production and an additional 3-5 employees focused on market sales offsite. Education and Retail A major part of our mission is to educate consumers of all ages about the science behind our seafood’s origins, and the importance of domestic food production. While this will occur with chefs and market customers using videos and other media, we would like to dedicate a small amount of space to a retail and education counter where the general public can learn, buy merchandise, and take home a few pounds of shrimp. Hours for the retail center will be limited, and initially appointments will be preferred. PC Agenda Page 19 DISCIPLINE G GENERAL NOTES AND INFORMATION DM DEMOLITION A ARCHITECTURE E ELECTRICAL FA FIRE ALARM FP FIRE PROTECTION M MECHANICAL P PLUMBING PA PUBLIC ASSEMBLY S STRUCTURAL SP SPRINKLER SERIES 0 COVER, SCHEDULES, GENERAL NOTES 1 SITE PLAN / PHASING PLANS / LIFE SAFETY PLAN 2 FLOOR PARTITION PLAN 3 REFLECTED CEILING PLAN 4 ELEVATIONS AND SECTIONS 5 CONSTRUCTION AND MILLWORK DETAILS 6 FINISH PLAN 7 FURNITURE, FIXTURE, AND EQUIPMENT PLAN 8 POWER AND COMMUNICATION PLAN SUFFIX IDENTIFIES MULTIPLE DRAWINGS WITHIN A SERIES DRAWING REVISION NUMBER ELEVATION1 A-500 1 A-500 SECTION 1 A-500 X ENLARGED PLAN COLUMN LINE OFFICE WO-195 ROOM NAME / NUMBER AREA NOT IN CONTRACT A-201.00 TRANSPARENTSEA CONTACT: STEVE SUTTON EMAIL: STEVE@TRANSPARENTSEAFARM.COM TEL: 518.764.0359 ARCHITECT: BAM ARCHITECTURE STUDIO SUITE 408 453 S SPRING ST LOS ANGELES, CA 90013 CONTACT: BRIAN SPENCE EMAIL: BSPENCE@BAM-STUDIO.COM TEL: 929.999.6280 MECHANICAL AND PLUMBING ENGINEER: CAPITAL ENGINEERING 2830 TEMPLE AVENUE LONG BEACH, CA 90806 CONTACT: LLOYD MARINER EMAIL: LMARINER@CAPITAL-ENGINEERING.COM TEL: 562.278.1205 STRUCTURAL ENGINEER: MHP STRUCTURAL ENGINEERS 3900 COVER ST LONG BEACH, CA 90808 CONTACT: KENNETH D. O'DELL, S.E. EMAIL: KODELL@MHPSE.COM TEL: 562.985.3200 ELECTRICAL ENGINEER: N.A. COHEN GROUP, INC. SUITE 500 15720 VENTURA BLVD ENCINO, CA 91436 CONTACT: JACK ARSLANIAN, P.E. EMAIL: JACKA@COHENGROUP.COM TEL: 818.355.1379 BUILDING TYPE: III-B BUILDING DESIGN: EXISTING PROPOSED TOTAL BUILDING AREA: 18,140 SF NO CHANGE BUILDING HEIGHT: 16'NO CHANGE BUILDING STORIES:1 NO CHANGE FULLY SPRINKLERED:YES NO CHANGE OCCUPANCY CALCS: OCCUPANCY TYPE: F-2 OCCUPANCY LOAD: 70 PERSONS SEE SHEET A-110 LIFE SAFETY PLAN FOR OCCUPANCY CALCULATIONS SCOPE OF WORK: EXISTING PROPOSED 1ST FLOOR: 18,140 GSF NO CHANGE TOTAL: 18,140 GSF NO CHANGE PROJECT DESCRIPTION: CONDITIONAL USE PERMIT (CUP) SUBMITTAL. DEMOLITION OF INTERIOR NON-STRUCTURAL PARTITIONS IN EXISTING WAREHOUSE AND OFFICE SPACE. WORK INCLUDES NON-BEARING PARTITIONS, MILLWORK, FINISHES, CEILINGS, INTERIOR AND EXTERIOR LIGHTING. RENOVATION OF EXISTING RESTROOMS TO MEET BUILDING REQUIREMENTS AND MEET PROJECT NEEDS. SITE: 12510 COLUMBIA WAY DOWNEY, CALIFORNIA 90242 APPLICABLE CODES: BUILDING: 2019 CALIFORNIA BUILDING CODE ELECTRICAL:2019 CALIFORNIA ELECTRICAL CODE MECHANICAL: 2019 CALIFORNIA MECHANICAL CODE PLUMBING:2019 CALIFORNIA CODE PLUMBING ENERGY:2019 CALIFORNIA ENERGY CODE SUSTAINABILITY: 2019 GREEN BUILDING CODE FIRE: 2019 CALIFORNIA FIRE CODE LOCAL:CITY OF DOWNEY MUNICIPAL BUILDING CODE AREA OF WORK PROPOSED EXTERIOR BUILDING FACADE SEE SHEET A-404 FOR EXTERIOR BUILDING RENDERINGS NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Avenue Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, California 90242 NOT FOR CONSTRUCTION PROJECT DATA PROJECT DIRECTORY DRAWING LIST SHEET NAME ARCHITECTURE SYMBOL SITE MAP N.A. Cohen Group, LLC Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.mhpse.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTALEXISTING STREET VIEW 8 /3 /2 0 2 0 1 1 :5 0 :0 8 A M COVER SHEET G-001 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA 12510 COLUMBIA WAY TRANSPARENTSEA DRAWING LIST SHEET NUMBER SHEET NAME 2 0 2 0 0 5 0 1 _C U P P R O G R E S S 2 0 2 0 0 5 0 6 _C U P S U B M I T T A L 2 0 2 0 0 8 0 3 _C U P C O M M E N T S ARCHITECTURE G-001 COVER SHEET X X X A-100 SITE PLAN X X X A-110 LIFE SAFETY PLAN X X X DM-201 DEMOLITION PARTITION PLAN X X X A-204 PARTITION PLAN X X X A-205 DIMENSIONED PLAN X X X A-300 REFLECTED CEILING PLAN NOTES X X X A-301 REFLECTED CEILING PLAN X X X A-302 PHOTOMETRIC PLAN - EXTERIOR LIGHTS X X X A-400 ELEVATION KEY PLAN X X X A-401 RESTROOMS - ENLARGED PLANS & SECTIONS X X X A-402 BUILDING EXTERIOR ELEVATIONS X X X A-403 BUILDING INTERIOR SECTIONS X X X A-404 BUILDING EXTERIOR ELEVATIONS - RENDERINGS X A-700 FLOOR FURNITURE, FIXTURE, AND EQUIPMENT LEGENDS X X X A-701 FURNITURE, FIXTURE, AND EQUIPMENT PLAN X X X 01 01 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS 01 PC Agenda Page 20 B C D E F G H I J K 5 5 4 4 3 3 1 1 2 2 A 20'-3" 93 ' - 0 " 20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0"20'-0" 26 ' - 8 " 20 ' - 0 " 6' - 8 " 21 ' - 7 " 180'-0" 6' - 9 " 14 6 ' - 4 " 290'-4" 40'-0" PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE CO L U M B I A W A Y 71 ' - 5 " 22'-0"5'-0" T Y P . 9 '-0 " 49'-6" TYP. 18'-0" 45'-0" NO PA R K I N G CL CL CL 9 '-0 " 18'-0" 8 '-0 " 4'-6" CL CL 2 4 '-0 " 9 '-8 " 5 '-0 " 1 0 1 '-1 1 " 1 4 6 '-4 " 1 1 1 1 2 3 4 3 4 5 6 7 8 9 10 1 1 1 2 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 2 1 18'-0" 5 6 7 7 7 7 EXISTING FACTORY WORKSHOP AND WAREHOUSE 8 9 10 11 12 22'-0"18'-0" 13 14 8 '-0 " 15 13 16 17 18 19 01 01 01 01 01 01 01 01 LT-1 LT-1 LT-1 LT-8 LT-8 01 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 20 20 21 21 2201 LT-9LT-9 01 01 PARKING SUMMARY NUMBER OF PARKING SPACES REQUIRED LAND USE ON SITE RETAIL SALES: - GENERAL RETAIL SHOPS AND COMMERCIAL USES MANUFACTURING/WAREHOUSING: - MANUFACTURING & INDUSTRIAL USES FINANCIAL, PROFESSIONAL SERVICES AND OFFICE USES: - PROFESSIONAL, BUSINESS AND OTHER OFFICES NOT LISTED 1 PER 250 SF OF GROSS FLOOR AREA 1 PER 500 SF OF GROSS FLOOR AREA, EXCEPT WHERE LOCATED IN A COMMERCIAL ZONE WHICH SHALL BE 1 SPACE PER 250 SF OF GROSS FLOOR AREA PARKING CALCULATIONS 600 GSF / 250 GSF = 2.40 PARKING SPACES 979 GSF / 300 GSF = 3.26 PARKING SPACES 1 PER 300 SF OF GROSS FLOOR AREA, MINIMUM OF (3) PARKING SPACES SHALL BE PROVIDED TOTAL 39 PARKING SPACES REQUIRED PARKING LANDSCAPING AND SITE SUMMARY TOTAL SF / QUANTITYSYMBOL DESCRIPTION REMARKS 413 SF 4 4 CARMEL CREEPER GROUND COVER SHRUB TREE EXISTING TO REMAIN PROPOSED DROUGHT TOLERANT GROUND COVER PER CITY OF DOWNEY MUNICIPAL CODE SECTION 9712 TABLE 9.7.3 "NON RESIDENTIAL PARKING REQUIREMENTS" 16,658 GSF / 500 GSF = 33.32 PARKING SPACES BUILDING IS LOCATED WITHIN ZONING: C-M (COMMERCIAL MANUFACTURING ZONE) PER CITY OF DOWNEY MUNICIPAL CODE, SECTION 9520.04 LANDSCAPING REQUIREMENTS: - ALL OFF STREET PARKING AREAS OF FIVE (4) OR MORE SPACES SHALL BE LANDSCAPED. ALL PARKING AREAS OF FIVE (5) TO TWENTY (20) SPACES SHALL CONTAIN A MINIMUM INTERIOR LANDSCAPED AREA OF FIVE (5) PERCENT OF THE TOTAL PARKING AREA, EXCLUSIVE OF LANDSCAPING WITHIN A FRONT OR SIDE SETBACK. ALL PARKING AREAS OF MORE THAN TWENTY (20) SPACES SHALL CONTAIN A MINIMUM INTERIOR LANDSCAPED AREA OF TEN (10) PERCENT OF THE TOTAL PARKING AREA, EXCLUSIVE OF LANDSCAPING WITHIN A FRONT OR SIDE SETBACK. SYMBOL PARKING SUMMARY REQUIRED STALLS 9' X 18' STANDARD TYPE OF STALLS 9' X 18' ACCESSIBLE STANDARD 1 9' X 18' VAN ACCESSIBLE STANDARD 41 1 0 PROPOSED ADDITIONAL STALLS EXISTING STALLS PROPOSED ADDITIONAL STALLS 1 37 1 0 0 0 PER CBC CODE SECTION 9712 TABLE 11B-208.2 "PARKING SPACES" MINIMUM NUMBER OF REQUIRED ACCESSIBLE PARKING SPACES SPACES PROVIDED FOR 26-50 SPACES IS 2, INCLUDING 1 VAN ACCESSIBLE SPACE TOTAL 43 EXISTING STALLS39 REQUIRED STALLS TOTAL STALLS PROVIDED 43 STALLS PROVIDED 1 41 1 EXISTING LANDSCAPING AREA: 412.79 SF PROPOSED LANDSCAPING AREA: 54.44 SF TOTAL LANDSCAPING AREA PROVIDED: 467.23 SF REQUIRED LANDSCAPING AREA: 24,247 SF X 0.10 = 2,424.7 SF EXISTING TO REMAIN SLURRY OR TOP COAT PROVIDE AT ALL UNEVEN AREAS TO FRONT OF GATE NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No.Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 0 A M SITE PLAN A-100 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA KEYNOTES KEY VALUE 1 EXISTING FENCE ALONG PERIMETER OF PROPERTY LINE TO REMAIN. 2 EXISTING FIRE RISER TO REMAIN. 3 EXISTING BUILDING ENTRANCE/EXIT. EXISTING KEYBOX AT ENTRY. 4 BUILDING EMERGENCY EXIT 5 EXISTING FIRE SPRINKLER CONNECTION TO REMAIN 6 EXISTING EQUIPMENT SHED TO REMAIN. 7 EXISTING ACCCESSIBLE ROUTE AND TRUNCATED DOMES TO REMAIN. 8 EXISTING SIDEWALK 9 EXISTING CURB AND GUTTER (WHERE OCCURS) TO REMAIN 10 EXISTING ASPHAULT PAVING AND STRIPING TO REMAIN. 11 PROVIDE ACCESSIBLE SIGNAGE AT VAN ACCESSIBLE AND ACCESSIBLE PARKING SPACES, TYP. 12 REMOVE AND REPLACE EXITING GATE WITH PROPOSED 20' WIDE, 6' HIGH, DOUBLE-DOOR HOLLOW IRON OR ALUMINUM MATERIAL MANUAL GATE. 13 TRASH ENCLOSURE PER DOWNEY MUNICIPAL CODE SECTION 9528.04. 14 PROVIDE NEW BLOCK LETTERING FOR BUILDING NUMBER AT ENTRANCE. 15 NO PARKING, INDENDED LOADING ZONE FOR VAND AND PICKUP TRUCKS. 16 PATCHING OF PAVING, PROVIDE SLURRY COAT OR TOP COAT TO GATE ONLY AND AS NOTED. FILL IN ALL UNEVEN AREAS, LOCATIONS TO BE VERIFIED IN FIELD. 17 CHAINLINK FENCE TO BE REMOVED ON THIS AREA ONLY. EXISTING FENCE TO REMAIN ELSEWHERE. 18 EXISTING TREE AND SHRUB TO REMAIN, PROVIDE GROUNDCOVER AROUND, TYP. 19 EXISTING GROUNDCOVER TO BE REMOVED AND REPLACED WITH CARMEL CREEPER GROUNDCOVER. 20 ARCHITECTURAL/DECORATIVE WALL SCONCE AT BUILDING ENTRANCE. 21 EXTERIOR BUILDING SECURITY LIGHTING ALONG PERIMETER OF BUILDING, SEE ELEVATIONS FOR MOUNTING HEIGHTS, TYP. PROVIDE LIGHTING FIXTURES AS NOTED ON THE REVISED LIGHTING CALCULATIONS. 22 PROVIDE NEW BLOCK LETTERING FOR BUILDING NUMBER AT BUILDING CORNER. SCALE: 3/32" = 1'-0" SITE PLAN1 01 01 01 01 01 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS 01 PC Agenda Page 21 B C D E F G H I J K 5 4 3 1 2 A 618 SF RETAIL 275 SF OFFICE 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) 6243 SF G02 - GROWOUT TANK AREA 2797 SF GO1 - GROWOUT TANK AREA 1392 SF SHRIMP PL NURSERY SYSTEM 342 SF PACKING ROOM 145 SF WASH DOWN AREA 3117 SF COMMON CIRCULATION 2 2 1 '-4 " 197'-10" 5 '-0 " S3 S1 EXIT B EXIT A S2 EQ-SUMP T G01 EQ-PLN CL EQ-PLN T/W STORAGE EQ-PLN T EQ-PLN T EQ-PLN CL EQ-PLN CL EQ-RFS EQ-O2 C EQ-O2 C EQ-O2 C EQ-DNR+P 464 SF WAREHOUSING 01 A-401 1 81 SF IT CLOSET 29 SF STORAGE 95 SF NON-GENDER SHOWER ROOM 83 SF NON-GENDER RESTROOM 83 SF NON-GENDER RESTROOM 122 SF BREAKROOM 13 SF JAN.CLOSET / STORAGE SYMBOL 1-HOUR FIRE-RATED PARTITION 2-HOUR FIRE-RATED PARTITION PARTITION DOOR 45 MIN. 90 MIN. 1. EXISTING FIRE PROTECTION AND LIFE SAFETY DEVICES, INCLUDING SPEAKERS, STROBES, EMERGENCY FIXTURES, EXIT LIGHTS, SMOKE DETECTORS AND SPRINKLERS TO BE REUSED TO FULLEST EXTENT POSSIBLE. 2. SEE ENGINEERING DRAWINGS FOR FIRE ALARM AND LIFE SAFETY DEVICES. 3. COORDINATE LOCATIONS OF ALL CEILING MOUNTED DEVICES WITH CEILING GRID, LIGHT FIXTURES AND ARCHITECT IN FIELD. NOTES: PATH OF PROGRESS EXIT A EXIT POINT NOT IN CONTRACT REMOTE POINT RECESSED CEILING MOUNTED/RECESSED WALL MOUNTED SELF-ILLUMINATING EXIT LIGHT, FURNISH AS REQ'D. EDGE LIT. SHADED QUADRANT INDICATES ILLUMINATED FACE. ARROWS INDICATE DIRECTION OF TRAVEL. COORDINATE WITH BUILDING STANDARD. S1 FIRE EXTINGUISHER CABINET: SEE FURNITURE, FIXTURE, AND EQUIPMENT PLAN FOR SPECIFICATION LIFE SAFETY LEGEND FEC SYMBOL 1-HOUR FIRE-RATED PARTITION, EXISTING 2-HOUR FIRE-RATED PARTITION, EXISTING PARTITION DOOR 45 MIN. 90 MIN. OCCUPANCY LOAD - PER TABLE 1004.1.2 EXIT WIDTH CAPACITY - PER CODE 1005.1 EXIT DOOR PROVIDED 36" REQUIRED (69 PERSONS / 2) * (0.2) = 6.9" THE CAPACITY OF MEANS OF EGRESS PROVIDING TRAVEL BY MEANS OF STAIRS SHALL BE 0.3 IN/PERSON. PROVIDING HORIZONTAL TRAVEL BY MEANS SUCH AS DOORS, RAMPS, OR HORIZONTAL EXITS SHALL BE 0.2 IN/PERSON. EXIT SEPARATION - PER CODE 7.5.1.2 DIAGONAL DISTANCE OF 1ST FLOOR 221'-4" MINIMUM REQUIRED 1/3 DIAGONAL DISTANCE OF 1ST FLOOR EXIT SEPARATION BETWEEN 2 EXITS ON 1ST FLOOR 73'-9" 197'-10" 197'-10" > 73'-9" = OK 7.5.1.2: WHERE TWO EXITS OF EXIT ACCESS DOORS ARE REQUIRED, THEY SHALL BE PLACED AT A DISTANCE FROM ONE ANOTHER NOT LESS THAN 1/3 OF THE LENGTH OF THE MAX. OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED. 1. PROJECT WILL COMPLY WITH THE 2019 CALIFORNIA BUILDING CODE. 2. WORK DOES NOT CONSTITUTE A CHANGE OF OCCUPANCY IN ACCORDANCE WITH THE CALIFORNIA BUILDING CODE. 3. EXISTING EGRESS/OCCUPANT LOAD NOT CHANGED. 2019 CALIFORNIA BUILDING CODE ACTUAL / REMARKS (IF APPLICABLE) F-2 TYPE III-B 400' (SPRINKLERED) TABLE 1017.2 50' 1020.4 MAX. TRAVEL DISTANCE: 190'-11" COMPLIES 44" MIN. MAX. DEAD END CORRIDOR: 37'-7" COMPLIES MIN. CORRIDOR WIDTH: 57" COMPLIES 0 RATING REQUIRED TABLE 1020.1 COMPLIES 100' PER 1006.2.1 COMMON PATH OF TRAVEL: 94'-0" COMPLIES LIFE SAFETY NOTES CODE CATEGORY OCCUPANCY CONSTRUCTION TYPE MAXIMUM TRAVEL DISTANCE MAXIMUM DEAD END CORRIDOR MINIMUM CORRIDOR WIDTH RATING OF CORRIDORS COMMON PATH OF TRAVEL PLUMBING FIXTURE COUNTS - PER PLUMBING CODE 422.1 (TOTAL FLOOR AREA) /(FLOOR AREA IN SF PER OCCUPANT) =MAX LOAD OCCUPANCY MINIMUM REQUIRED BY CODE (MAX LOAD OCCUPANCY / NUMBER OF EXITS) x (0.3 OR 0.2) = EXIT DOOR WIDTH REQUIRED FUNCTION OF SPACE FLOOR AREA IN SF PER OCCUPANT ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM 300 GROSS TOTAL FLOOR AREA MAX LOAD OCCUPANCY 520 SF 2 PERSON HATCH PATTERN AGRICULTURAL 300 GROSS 15,776 SF 53 PERSONS TOTALBUSINESS 100 GROSS 1,362 14 PERSONS - 17,658 SF 69 PERSONS - 32" USABLE AREA (SF) OCCUPANT LOAD FACTOR OCCUPANT LOAD FIXTURES REQUIRED FIXTURES PROVIDED F-2 17,701 SF 2,000 17,658 / 2,000 = 9 GENDER COUNT: 9 / 2 = 4.5 M (1:1-50): 1 WC, 1 L W (1:1-50): 1 WC, 1 L M: 1 WC, 1 U, 1 L W: 2 WC, 2 L OCCUPANCY GROUP F-2 TYPE III-B NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 0 A M LIFE SAFETY PLAN A-110 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA 0 SCALE: 1/8" = 1'-0" FIRST FLOOR LIFE SAFETY PLAN1 EXIT ACCESS TRAVEL DISTANCE MAXIMUM TRAVEL DISTANCE FOR OCCUPANCY TYPE B; WITH SPRINKLER SYSTEM (INTERNATIONAL BUILDING CODE ICC, CHAPTER 10 TABLE 1016.2): 300' START POINT EXIT POINT EGRESS TRAVEL DISTANCE S1 EXIT A 182'-11" S1 EXIT B 112'-1" S2 EXIT A 158'-4" S2 EXIT B 107'-11" S3 EXIT A 103'-9" S3 EXIT B 190'-11" REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 22 UPUPUPUPUP UP UP UP B C D E F G H I J K 5 4 3 1 2 A 618 SF RETAIL 275 SF OFFICE 5 '-0 " 9 2 '-0 " 4 6 '-0 " T Y P . 3 2 '-0 " T Y P . 3 8 '-0 " 10'-0"19'-0" 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) 1392 SF SHRIMP PL NURSERY SYSTEM 6 " T Y P . 6 " T Y P . 179'-5" 6" TYP. 6 " T Y P . 6 " T Y P . 2 '-0 " 16'-10" 2'-0"2'-0"6 " 2 '-0 " 3 '-0 " 5 '-0 " 2'-0" 2'-0"2'-0"6 " 2 '-0 "6 '-1 0 " 1 '-0 " 1 '-0 " 1 '-0 " 4'-1" 4'-10" 9" 20'-6" 1 6 '-8 " 3'-9" 4 '-1 0 " T Y P . 5 '-0 " 1 6 '-6 " 145 SF WASH DOWN AREA 10'-7"8'-0" 3117 SF COMMON CIRCULATION TYP. 12'-6" TYP. 4'-0" 6" TYP.6" TYP. TYP. 12'-6" 6" TYP. TYP. 4'-0" 342 SF PACKING ROOM 2797 SF GO1 - GROWOUT TANK AREA 6243 SF G02 - GROWOUT TANK AREA TYP. 13'-0" TYP. 4'-0" 6" TYP. TYP. 13'-0" 6" TYP. TYP. 4'-0" 6" TYP. 6 " T Y P . 3 2 '-0 " T Y P . 6 " T Y P . 3'-2" 3 '-0 " 3'-0" 3 '-0 " 0.13 0.130.13 100 107 108E001 E002 E006 E007 E008 E003 0.13 464 SF WAREHOUSING 1 0.13 109 A-401 1 01 81 SF IT CLOSET 29 SF STORAGE 95 SF NON-GENDER SHOWER ROOM 83 SF NON-GENDER RESTROOM 83 SF NON-GENDER RESTROOM 122 SF BREAKROOM 13 SF JAN.CLOSET / STORAGE E004 E005 102 103 104 105 106 EXISTING LOWER PARTITION 1 HR RATED 2 HR RATED PARTITION LEGEND NEW PARTITION NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 2 A M PARTITION PLAN A-204 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA 0 SCALE: 1/8" = 1'-0" PARTITION PLAN1 KEYNOTES KEY VALUE 1 PROPOSED NEW EXTERIOR DOOR. 01 01 01 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 23 UPUPUPUPUP UPUPUP B C D E F G H I J K 5 4 3 1 2 A 618 SF RETAIL 275 SF OFFICE 9 2 '-0 " 4 6 '-0 " T Y P . 3 2 '-0 " T Y P . 3 8 '-0 " 10'-0"19'-0" 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) 1392 SF SHRIMP PL NURSERY SYSTEM 6 " T Y P . 6 " T Y P . 179'-5" 6" TYP. 6 " T Y P . 6 " T Y P . 2 '-0 " 16'-10" 2'-0"2'-0"6 " 2 '-0 " 3 '-0 " 5 '-0 " 2'-0" 2'-0"2'-0"6 " 2 '-0 "6 '-1 0 " 1 '-0 " 1 '-0 " 1 '-0 " 4'-1" 4'-10" 9" 20'-6" 1 6 '-8 " 3'-9" OXD MBBR 1 OXD MBBR 2 OXD MBBR 3 4 '-1 0 " T Y P . 5 '-0 " 1 6 '-6 " 145 SF WASH DOWN AREA 10'-7"8'-0" 1 8 '-2 " 3117 SF COMMON CIRCULATION TYP. 12'-6" TYP. 4'-0" 6" TYP.6" TYP. TYP. 12'-6" 6" TYP. TYP. 4'-0" 342 SF PACKING ROOM 2797 SF GO1 - GROWOUT TANK AREA 6243 SF G02 - GROWOUT TANK AREA TYP. 13'-0" TYP. 4'-0" 6" TYP. TYP. 13'-0" 6" TYP. TYP. 4'-0" 6" TYP. 6 " T Y P . 3 2 '-0 " T Y P . 6 " T Y P . 3'-2" 3 '-0 " 3'-0" 3 '-0 " 1 4 '-0 " 19'-9" 17'-9"2'-0" 7 '-4 " 5 0 '-0 " T Y P . 1 '-4 " T Y P . T Y P . 4 '-9 " 1 '-6 " T Y P . 1'-6"9 " 18'-8" TYP.1'-4" TYP. 1'-6" TYP. 19'-9" 7 1 '-5 " 20'-3" 2 1 '-7 " 18'-0"18'-0" A-401 1 TYP. 4'-0" 464 SF WAREHOUSING 2 3 '-7 " 3 2 '-1 " 1 0 '-6 " 7 '-1 0 " 7 '-1 0 " 1 1 '-3 " 7 '-0 " 11'-7" 3'-0" 4 '-2 " 5 '-6 " 4'-6" 01 81 SF IT CLOSET 29 SF STORAGE 95 SF NON-GENDER SHOWER ROOM 83 SF NON-GENDER RESTROOM 13 SF JAN.CLOSET / STORAGE 83 SF NON-GENDER RESTROOM 122 SF BREAKROOM NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 2 A M DIMENSIONED PLAN A-205 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA SCALE: 1/8" = 1'-0" DIMENSIONED PLAN1 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 24 REFLECTED CEILING PLAN GENERAL NOTES 1. EACH FIXTURE LOCATED IN DROPPED ACOUSTICAL CEILING SHALL BE CENTERED ON EACH 2' X 2' TILE, AS SHOWN. 2. ALL ELECTRICAL SWITCHES AND COVER PLATES SHALL BE MOUNTED VERTICALLY, STRAIGHT, ALIGNED, AND SHALL MATCH SPEC INFO AS NOTED. 3. CEILING SUSPENSION RODS AND BLACK IRONS SHALL BE HUNG BY SECURING TO THE CLIP TABS ON THE STRUCTURAL METAL DECK. NO SCREWS OR OTHER MECHANICAL STUDS OR FASTENERS SHALL BE USED IN THE DECK UNLESS APPROVED IN WRITING BY THE BUILDING MANAGEMENT. 4. ALL DIMMERS, SWITCHES, AND COVERPLATES TO BE LUTRON; MODEL: DIVA, COLOR: WHITE U.O.N. COORDINATE WITH BUILDING STANDARDS. 5. LETTERS NEXT TO LIGHT FIXTURES INDICATE SPECIFICATION INFORMATION FOR EACH FIXTURE. SEE REFLECTED CEILING PLAN LEGEND FOR CLARIFICATION. 6. SEE ENGINEERING PLANS FOR SWITCHING INFORMATION. 7. ALL SWITCHES IN A GROUP ARE TO BE GANGED WHERE POSSIBLE WITH A SINGLE COVERPLATE. 8. PROVIDE MINIMUM OF (1) ONE LIGHT SWITCH PER ROOM U.O.N. 9. ALL LAMPS SHALL BE RATED ATLEAST 3000°K COLOR TEMPERATURE. LAMPS THAT DO NOT MEET THIS SPECIFICATIONS WILL NOT BE ACCEPTED. 10. ANY ADDITIONAL EQUIPMENT NEEDED FOR INSTALLATION OF THE SPECIFIED FIXTURES SHALL BE PROVIDED BY THE CONTRACTOR. 11. ANY NECESSARY GRID LOCATION CHANGES OR FIXTURE LOCATION CHANGES SHALL BE APPROVED BY THE ARCHITECT PRIOR TO INSTALLATION. 12. ALL DIMENSIONS ARE TO THE CENTER OF THE FIXTURE AND ARE TAKEN FROM THE FINISHED FACE OF WALL. 13. SEE SECTIONS AND ELEVATIONS FOR CEILING HEIGHTS NOT NOTED. 14. LAMP ALL FIXTURES FOLLOWING SUBSTANTIAL COMPLETION. 15. EXISTING LIGHTING TO REMAIN WHERE NOTED. CONTRACTOR TO SURVEY EXISTING LOADS AND CIRCUITING, AND RE-CIRCUIT/REWIRE AS NECESSARY. 16. CONTRACTOR TO FURNISH AND INSTALL FIRE AND SMOKE DAMPERS AS NECESSARY IN NEW AND EXISTING DUCTWORK TO ACHIEVE REQUIRED FIRE COMPARTMENTALIZATION. 17. SEE MECHANICAL DRAWINGS FOR EXTENT OF REQUIRED DUCTWORK TO REMAIN. 18. NOTIFY ARCHITECT IF GRID LAYOUT RESULTS IN A TILE 6" OR LESS IN ANY DIMENSION PRIOR TO INSTALLATION. 19. THERE SHALL BE NOTHING FASTENED TO THE FACE OF THE WINDOW BLIND POCKET UNDER ANY CIRCUMSTANCE. 20. PROTECT, TO THE SATISFACTION OF THE BUILDING MANAGEMENT, EXISTING DUCTS, SMOKE DETECTORS, OR REPLACE THEM FOLLOWING SUBSTANTIAL COMPLETION. 21. CAULK BETWEEN CEILING GRID EDGE AND WALLS AT ALL VISIBLE LOCATIONS. MATCH COLOR OF CAULK TO COLOR OF CEILING GRID. 22. LIGHTING FIXTURE COMPONENTS SHALL BE SUITABLE FOR THE VOLTAGE OF THE BUILDIGN CIRCUITES TO WHICH THEY ARE APPLIED. DIMMERS SHALL BE SIZED FOR INDICATED LOADS. 23. ALL DIMMING CIRCUITS SHALL HAVE SEPARATE NEUTRALS. SEE ELECTRICAL DRAWINGS. 24. ALL BALLASTS TO BE APPROVED BY THE BUILDING MANAGEMENT. SEE BUILDING RULES AND REGULATIONS. 25. FURNISH AND INSTALL HOLD-DOWN CLIPS FOR RECESSED PARABOLIC FIXTURES., TYP. 26. PAINT ALL EXPOSED CUT EDGES OF CEILING TILES WITH MANUFACTURER-APPROVED PAINT, TYP. MATCH COLOR TO TILE. 27. FURNISH AND INSTALL ACRYLIC LIGHT SHELF COVER AT ALL OPEN LIGHT FIXTURES. SEE FINISH ELEVATIONS AND SECTIONS. 28. GC. SHALL PROVIDE TEMPORARY EXIT LIGHTING AND SIGNAGE WHEN/WHERE APPLICABLE. COORDINATE WITH ARCHITECT, TYP. CEILING TYPE LEGEND SYMBOL DESCRIPTION REMARKS B 9'-0"CEILING TYPE / CEILING HEIGHT FURNISH AND INSTALL EDGE BEAD WITH JOINT COMPOUND AT ALL EXPOSED GYPSUM WALLBOARD EDGES. TAPE SPACKLE AND PREPARE FOR NEW FINISH. GYPSUM WALLBOARD CEILING WITH GWB FASCIA AT CEILING HEIGHT CHANGES FURNISH AND INSTALL EDGE BEAD WITH JOINT COMPOUND AT ALL EXPOSED GYPSUM WALLBOARD EDGES. TAPE SPACKLE AND PREPARE FOR NEW FINISH.A 1 EXISTING TO REMAINE OPEN TO STRUCTURE ---S NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 3 A M REFLECTED CEILING PLAN NOTES A-300 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA LIGHTING FIXTURE SCHEDULE SYMBOL TYPE DESCRIPTION MANUFACTURER MODEL NUMBER BOTTOM OF FIXTURE HEIGHT COLOR TEMPERATURE COLOR RENDERING INDEX MOUNTING REMARKS LT-1 EXTERIOR SECURITY LIGHT LITHONIA LIGHTING DSXW1 LED 10C 40K T2M MVOLT DBLXD SEE ELEVATION MOUNTING HEIGHTS 4000K 80 WALL MOUNTED DSXW1 LED WITH 1 LIGHT ENGINE 10 LED's 530mA DRIVER 3000K LED TYPE 3 MEDIUM OPTIC LT-2 LED DOWNLIGHT LITHONIA LIGHTING 6JBK-SQ-40K-90CRI-MW SEE RCP 4000K 80 SURFACE MOUNTED DIMMABLE, DAMP-PROOF LT-3 UNDERCABINET LIGHTING OPTIC ARTS FLEX DC FLEXDC-40-35-24-44-FLC1-SEE RCP FOR LENGTH SEE RCP 3500K 80 SURFACE MOUNTED LT-4 LED 2X4 LIGHT LITHONIA LIGHTING 2VTX4-48L-ADP-EZ1-LP835 SEE RCP 3500K 82 SURFACE MOUNTED LT-5 LED 1X4 LIGHT LITHONIA LIGHTING UFIT-L48-6000LM-SEF-MVOLT-GZ10-40K-80C RI-WH 10'-0" A.F.F.4000K 80 PENDANT DIMMABLE, DAMP-PROOF LT-6 LED UTILITY LIGHT LITHONIA LIGHTING WL2 18L EZ1 LP835 8'-0" A.F.F.3500K 80 WALL MOUNTED LED UTILITY LIGHT LT-7 LED 1X4 LIGHT LITHONIA LIGHTING UFIT-L48-6000LM-SEF-MVOLT-GZ10-40K-80C RI-WH SEE RCP 4000K 80 SURFACE MOUNTED LT-8 OUTDOOR WALL SCONCE LIGHT FIXTURE Y LIGHTING - LOUIS POULSEN 5743909379 SEE ELEVATION MOUNTING HEIGHTS 3000K 90 WALL MOUNTED LED ARCHITECTURAL WALL SCONCE, DECORATIVE LT-9 LED FLOOD LIGHT LITHONIA LIGHTING DSXF3 LED-6-P2-40K-70CRI-WFL-MVOLT-DBLD SEE ELEVATION MOUNTING HEIGHTS 4000K 70 WALL MOUNTED REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS 01 PC Agenda Page 25 B C D E F G H I J K 5 4 3 1 2 A 618 SF RETAIL 275 SF OFFICE 145 SF WASH DOWN AREA 342 SF PACKING ROOM 3117 SF COMMON CIRCULATION 2797 SF GO1 - GROWOUT TANK AREA 1392 SF SHRIMP PL NURSERY SYSTEM 6243 SF G02 - GROWOUT TANK AREA 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) A1 8'-9" A1 8'-9" A1 8'-9" A1 8'-9" A1 8'-9" A1 8'-9" LT-4 S 14'-0" A1 12'-0" LT-4 LT-4 LT-4 LT-4 6 '-0 " 8'-0" LT-3 LT-4 LT-4 LT-4LT-4 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5 LT-5LT-5 E Q E Q E Q S 14'-0" S 14'-0" LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 LT-7 EQ 8'-0" EQ E Q E Q 1 E Q E Q 01 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-8 LT-8 01 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 LT-1 01 LT-1 10'-0"10'-0" 6 '-6 " 6 '-6 " E Q E Q E Q E Q E Q LT-1LT-1 EQ EQ EQ EQ EQ EQ EQ EQ A1 8'-9" A1 8'-9" A1 8'-9" LT-4 S 14'-0" LT-2 LT-2 LT-2 LT-2 LT-2 LT-6 LT-2LT-2 LT-2 LT-2 LT-2 LT-2 LT-6 LT-2 LT-2 LT-2 LT-2 LT-2 LT-4 LT-4 01 01 01 01 2 2 LT-9LT-9 01 01 3 01 NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 3 A M REFLECTED CEILING PLAN A-301 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA 0 SCALE: 1/8" = 1'-0" FIRST FLOOR CEILING PLAN1 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS KEYNOTES KEY VALUE 1 EXISTING SKYLIGHTS TO REMAIN. LOCATION TO BE VERIFIED IN FIELD, TYP. 2 ARCHITECTURAL/DECORATIVE WALL SCONCE AT BUILDING ENTRANCE. 3 PROVIDE EXTERIOR BUILDING LIGHTING AS SHOWN ON THE REVISED LIGHTING CALCULATIONS. 01 PC Agenda Page 26 NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 3 A M PHOTOMETRIC PLAN - EXTERIOR LIGHTS A-302 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 27 UPUPUPUP UP UP UP A-4023 B C D E F G H I J K 5 4 3 1 2 A 618 SF RETAIL 275 SF OFFICE 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) 1392 SF SHRIMP PL NURSERY SYSTEM 145 SF WASH DOWN AREA 3117 SF COMMON CIRCULATION 342 SF PACKING ROOM 2797 SF GO1 - GROWOUT TANK AREA 6243 SF G02 - GROWOUT TANK AREA A-402 2 A-402 1 A-402 4 1 A-403 3 A-403 2 A-403 4 A-403 464 SF WAREHOUSING 01 A-404 1 A-404 4 A-404 2 A-4043 01 01 01 01 A-401 1 A-40113 11 10 12 NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 4 A M ELEVATION KEY PLAN A-400 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA SCALE: 1/8" = 1'-0" ELEVATION KEY PLAN1 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 28 1 8 " 1 8 " 4 4 " 4 4 " 6 0 " 18" 18 " B C 4 A-401 15 14 17 16 A-4019 6 7 8 A-4015 2 3 4 8 1/2" 8 1/2" C L C L C L C L C L C L TYP. 4'-0" T Y P . 2 '-6 " C L M I N . 1 '-6 " MIN. 5'-0" M I N . 4 '-6 " 1 '-6 " 3 '-6 " 7 '-0 " 1 0 '-6 " 2'-1" 1'-3" 3 '-0 " 6 "1'-0" 3'-6" 1 '-6 " 4'-0" MIN. 5 '-0 " M I N . 4'-8" MIN. TYP. 4'-0" T Y P . 2 '-6 " 1 '-6 " 3'-0" 4 '-2 " M I N . 1 '-6 " MIN. 5'-0" M I N . 4 '-6 " 1 '-6 " 4'-0" TYP. T Y P . 2 '-6 " 3 '-0 " 6 "1'-0" 3'-6" 1 '-6 " 4'-8" MIN. 5 '-0 " M I N . 4'-0" MIN. M I N . 1 '-6 " MIN. 5'-0" M I N . 4 '-6 " M I N . 1 '-6 " MIN. 5'-0" M I N . 4 '-6 " 1 '-6 " 1'-0" 3'-6" 4'-0" MIN. TYP. 4'-0" T Y P . 2 '-6 " 5 '-0 " M I N . 4'-8" MIN. 1 '-6 " 7 '-1 0 " 7 '-1 0 " 5 '-6 " 4'-6" 6" 4'-2" 6" 1 '-6 " 1 '-0 " 6 " 1"3" 3 '-0 " 3'-0" 122 SF BREAKROOM 83 SF NON-GENDER RESTROOM 83 SF NON-GENDER RESTROOM 95 SF NON-GENDER SHOWER ROOM 29 SF STORAGE 7 '-0 "M I N . 1 '-6 " MIN. 5'-0" M I N . 4 '-6 " 81 SF IT CLOSET 13 SF JAN.CLOSET / STORAGE 1'-6" 3 '-0 " 4 '-0 " 6'-2" A-40113 11 10 12 NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 5 A M RESTROOMS - ENLARGED PLANS & SECTIONS A-401 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS SCALE: 3/8" = 1'-0" PARTITION PLAN - TESTFIT 01 - RESTROOM ENLARGED PLAN - REVISION1 SCALE: 3/8" = 1'-0" NON-GENDER RESTROOM_NORTH ELEVATION2 SCALE: 3/8" = 1'-0" NON-GENDER RESTROOM_EAST ELEVATION3 SCALE: 3/8" = 1'-0" NON-GENDER RESTROOM_SOUTH ELEVATION4 SCALE: 3/8" = 1'-0" NON-GENDER RESTROOM_WEST ELEVATION5 SCALE: 3/8" = 1'-0" NON-GENDER SHOWER ROOM_NORTH ELEVATION6 SCALE: 3/8" = 1'-0" NON-GENDER SHOWER ROOM_EAST ELEVATION7 SCALE: 3/8" = 1'-0" NON-GENDER SHOWER ROOM_SOUTH ELEVATION8 SCALE: 3/8" = 1'-0" NON-GENDER SHOWER ROOM_WEST ELEVATION9 SCALE: 3/8" = 1'-0" BREAKROOM - NORTH ELEVATION10 SCALE: 3/8" = 1'-0" BREAKROOM - EAST ELEVATION11 SCALE: 3/8" = 1'-0" BREAKROOM - SOUTH ELEVATION12 SCALE: 3/8" = 1'-0" BREAKROOM - WEST ELEVATION13 SCALE: 3/8" = 1'-0" IT CLOSET_NORTH ELEVATION14 SCALE: 3/8" = 1'-0" IT CLOSET_EAST ELEVATION15 SCALE: 3/8" = 1'-0" IT CLOSET_SOUTH ELEVATION16 SCALE: 3/8" = 1'-0" IT CLOSET_WEST ELEVATION17 01 PC Agenda Page 29 GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" 54312 1 0 '-0 " T Y P . 3 '-8 " T Y P . 3 '-6 " TYP. 3'-6" 7 '-2 " 6'-9" TYP. 3'-10" 1 0 '-0 " 8'-0" 1 A-403 2 A-403 ROOF -HIGHEST POINT 19'-6" 1 5 '-0 " O .C . T Y P . 9 '-0 " O .C . T Y P . 7 '-4 " GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" BCDEFGHIJK A 18'-0" 1 0 '-0 " 1 0 '-0 " 18'-0" 3 A-403 4 A-403 ROOF -HIGHEST POINT 19'-6" 9 '-0 " O .C . T Y P . 1 2 '-0 " O .C . 1 5 '-0 " O .C . T Y P . H E I G H T & M O U N T I N G T O B E V .I .F ., T Y P . F L O O D L I G H T GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" 5 4 3 12 1 A-403 2 A-403 ROOF -HIGHEST POINT 19'-6" 1 5 '-1 " O .C . T Y P . GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" B C D E F G H I J KA 3 A-403 4 A-403 ROOF -HIGHEST POINT 19'-6" NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 6 A M BUILDING EXTERIOR ELEVATIONS A-402 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_WEST ELEVATION1 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_NORTH ELEVATION2 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_EAST ELEVATION3 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_SOUTH ELEVATION4 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 30 GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" B C D E F G H I J KA 3 A-403 4 A-403 ROOF -HIGHEST POINT 19'-6" GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" B C D E F G H I J KA 3 A-403 4 A-403 ROOF -HIGHEST POINT 19'-6" T Y P . 6 '-0 " T Y P . 3 '-0 " GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" 54312 1 A-403 2 A-403 ROOF -HIGHEST POINT 19'-6" GROUND 0" STRUCTURE -BOTTOM OF BEAM 14'-0" ROOF PARAPET 16'-0" 54312 1 A-403 2 A-403 ROOF -HIGHEST POINT 19'-6" T Y P . 3 '-0 "T Y P . 6 '-0 " T Y P . 1 1 '-0 " NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 7 A M BUILDING INTERIOR SECTIONS A-403 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA SCALE: 1/8" = 1'-0" SECTION 11 SCALE: 1/8" = 1'-0" SECTION 22 SCALE: 1/8" = 1'-0" SECTION 33 SCALE: 1/8" = 1'-0" SECTION 44 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 31 PAINT COLORS SHERWIN WILLIAMS SW6243 DISTANCE SHERWIN WILLIAMS SW6238 ICYCLE SHERWIN WILLIAMS SW6529 SCANDA SHERWIN WILLIAMS SW7076 CYBERSPACE SHERWIN WILLIAMS SW6242 BRACING BLUE NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 8 A M BUILDING EXTERIOR ELEVATIONS - RENDERINGS A-404 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_EAST ELEVATION - RENDERING3 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_NORTH ELEVATION - RENDERING2 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_SOUTH ELEVATION - RENDERING4 SCALE: 1/8" = 1'-0" BUILDING EXTERIOR_WEST ELEVATION - RENDERING1 PC Agenda Page 32 FURNITURE FIXTURE AND EQUIPMENT NOTES 1. ELECTRIC AND DATA RECEPTACLES SHOWN FOR COORDINATION PURPOSES ONLY. SEE ELECTRICAL DRAWINGS FOR CIRCUITING. 2. GC SHALL PROVIDE AND INSTALL SOLAR SHADES ON ALL PERIMETER WINDOWS. ARCHITECT TO CONFIRM COLOR PRIOR TO ORDER AND INSTALLTION. SEE DETAIL SHEETS FOR MOUNTING DETAILS AND POWER PLAN FOR POWER REQUIREMENTS. CONTRACTOR TO COORDINATE WITH BUILDING MANAGEMENT'S INSTALLER. 3. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY FURNITURE VENDOR AND INSTALLER PRIOR TO ORDER. CONTACT ARCHITECT PRIOR TO FURNITURE ORDER FOR ANY DISCREPANCIES. CLIENT AND ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY COSTS ASSOCIATED WITH MODIFYING FURNITURE TO FIT FIELD CONDITIONS. 4. ALL WHIP LOCATIONS TO BE CONFIRMED AND CLEARLY NOTED IN PLANS PROVIDED BY FURNITURE VENDOR. CONTACT ARCHITECT FOR ANY DISCREPANCIES. 5. ALL ELECTRICAL AND DATA LOCATIONS SHALL BE CONFIRMED IN THE FIELD BY THE FURNITURE VENDOR PRIOR TO WIRING AND INSTALLATION. 6. FURNITURE VENDOR SHALL PROVIDE SPECIFICATIONS OF THE PROPOSED WIRING CONFIGURATIONS AND COORDINATE WITH ELECTRICAL ENGINEER. CLIENT AND ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY COSTS ASSOCIATED WITH MODIFYING ELECTRICAL COMPONENTS TO FIT FIELD CONDITIONS. 7. FURNITURE VENDOR SHALL PROVIDE AXONOMETRIC AND INSTALLATION PLAN DRAWINGS IN .DWG AND .PDF FORMAT WITH ALL QUOTES. ARCHITECT WILL NOT REVIEW FURNITURE QUOTE UNTIL AND AXONOMETRIC AND PLAN DRAWINGS ARE RECEIVED. PROPOSAL APPROVAL IS CONTIGENT ON VENDOR PROVIDING INSTALLATION PLAN DRAWINGS. 8. ALLOW 12" MINIMUM CLEARANCE IN FRONT OF INDUCTION UNIT TO ALLOW FOR MAINTENANCE AND CLEANING. NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 8 A M FLOOR FURNITURE, FIXTURE, AND EQUIPMENT LEGENDS A-700 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA REVISIONS No. Date Description PC Agenda Page 33 DN UPUPUPUP UP UP UP B C D E F G H I J K 5 4 3 1 2 A EQ-SUMP T G01 EQ-PLN CL EQ-WH+BK 86" EQ-DP G01 EQ-WH SWP EQ-PLN T/W STORAGE EQ-PLN T EQ-PLN T EQ-PLN CL EQ-PLN CL EQ-DNR+P EQ-RFS EQ-O2 C EQ-O2 C EQ-O2 C EQ-DF EQ-WH+BK 96" EQ-PWH SWP EQ-VAL VP EQ-VAL AC EQ-UV DLEQ-OWS EQ-VAL T EQ-VAL T EQ-RFSUF P EQ-DNRWS P EQ-BWS P EQ-MRP EQ-MRP EQ-MRP EQ-DF BWP EQ-HC EQ-HC EQ-SH EQ-2C SINK EQ-2C SINK EQ-PLN H EQ-PLN P EQ-PLN H EQ-PLN P EQ-UV DL EQ-UV DL 618 SF RETAIL 275 SF OFFICE 3117 SF COMMON CIRCULATION 342 SF PACKING ROOM 145 SF WASH DOWN AREA 2797 SF GO1 - GROWOUT TANK AREA 1392 SF SHRIMP PL NURSERY SYSTEM 6243 SF G02 - GROWOUT TANK AREA 1769 SF RECIRCULATING AQUACULTURE SYSTEM (RAS) EQ-3C SINK EQ-HW SINK FEC 19'-9" 7 '-4 " 2 3 '-7 " 3 2 '-1 " 464 SF WAREHOUSING 6 '-6 " 1 1 '-0 " 6 '-8 1 /2 " 4'-0" 6'-6" 2'-0" 7'-11" 4'-10" 5'-2" REF FRZR TNK 81 SF IT CLOSET 95 SF NON-GENDER SHOWER ROOM 29 SF STORAGE 83 SF NON-GENDER RESTROOM 13 SF JAN.CLOSET / STORAGE 83 SF NON-GENDER RESTROOM 122 SF BREAKROOM A-401 1 01 NORTH copyright date: 01 2020.04.15 INTERNAL REVIEW No. Date Description 04.01.2020 ISSUANCES All drawings and written materials represneted on this sheet constitute the copyrighted work and are the sole property of BAM Architecture Studio. This sheet may not be reproduced or copied in whole or in part, nor may any of the drawings or written materials appearing within, be incorporated into another work for any reason without the written consent of BAM Architecture Studio. This sheet must be returned upon the request of the Architect. 453 S Spring St Suite 408 Los Angeles, California 90013 T: 213.465.4334 www.bam-studio.com Capital Engineering 2830 Temple Ave Long Beach, California 90806 T: 310.328.3955 www.capital-engineering.com MHP Structural Engineers 3900 Cover St Long Beach, California 90808 T: 562.985.3200 www.mhpse.com 12510 Columbia Way Downey, CA 90242 T: 213.465.4334 NOT FOR CONSTRUCTION N.A. Cohen Group, Inc. Suite 500 15720 Ventura Blvd Encino, California 91436 T: 818.461.1420 F: 818.461.1424 www.nacohengroup.com 02 2020.04.22 TESTFIT 03 2020.04.29 TESTFIT 04 2020.05.01 CUP PROGRESS 05 2020.05.06 CUP SUBMITTAL 8 /3 /2 0 2 0 1 1 :5 0 :0 8 A M FURNITURE, FIXTURE, AND EQUIPMENT PLAN A-701 Project No. 19-126.002 12510 COLUMBIA WAY TRANSPARENTSEA 0 SCALE: 1/8" = 1'-0" FIRST FLOOR FURNITURE, FIXTURE & EQUIPMENT PLAN1 REVISIONS No. Date Description 01 2020.08.03 CUP COMMENTS PC Agenda Page 34