HomeMy WebLinkAboutPC Resolution 15-2908RESOLUTION NO. 15 -2908
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
DOWNEY APPROVING SITE PLAN REVIEW APPLICATION PLN -14 -
00175, A REQUEST TO DEVELOP A FOUR -UNIT TOWNHOUSE
CONDOMINIUM PROJECT ON THE PROPERTY AT 8603 IMPERIAL
HIGHWAY, ZONED MULTIPLE - FAMILY RESIDENTIAL OWNERSHIP
(R -3 -O).
THE PLANNING COMMISSION OF THE CITY OF DOWNEY DOES RESOLVE
AS FOLLOWS:
SECTION 1. The Planning Commission of the City of Downey does hereby find,
determine and declare that:
A. A planning application was filed by Mr. Mike Tello, serving as authorized
representative, on behalf of Chandrakant Patel, project applicant,
petitioning approval of Site Plan Review No. PLN -14- 00175, a request to
develop a 4 -unit townhouse condominium development at 8603 Imperial
Highway (project site).
B. The project site is zoned Multiple - Family Residential Ownership zone, (R-
3 -0), and maintains the corresponding Medium Density Residential
designation on the General Plan's land use diagram.
C. The authorized agent for the development also filed two other planning
applications in conjunction with Site Plan Review Application PLN — 14 —
00175, both for the purpose of developing the contemplated 4 -unit
townhouse condominium project. They include Tentative Tract Map No.
72992 and a 3 -part zone variance request seeking relief from the R -3 -0
zone's side and rear yard building setback standards and variable building
height requirement.
D. The Los Angeles County Tax Assessor's Office identifies the property
under consideration, 8603 Imperial Highway, as Assessor Parcel No.
6261- 011 -033.
E. On January 15, 2015, Planning Division Staff deemed the subject
application, PLN -14- 00175, complete and notified the project applicant
that the Planning Commission would consider the application on March
18, 2015.
F. The Planning Commission held a duly- noticed public hearing on March 18,
2015, and after fully considering all oral and written testimony and facts
and opinions offered at the aforesaid public hearing, adopted Resolution
No. 15 -2908, approving Site Plan Review PLN -14- 00175.
Resolution No. 15 - 2908
Planning Commission
SECTION 2. Having considered all of the oral and written evidence
presented to it at said public hearing, the Planning Commission further finds,
determines and declares that:
That the site plan is consistent with the goals and policies embodied in the
General Plan and other applicable plans and policies adopted by the City
Council. Developing the 4 -unit townhouse condominium project is
consistent with the General Plan in that it will implement a host of General
Plan goals, policies and programs. They include: (1) General Plan
Program 1.4.3.1. "Promote ownership -based housing, such as
condominiums, townhouses, and planned unit developments." Project
implementation involves developing ownership units, townhouse
condominiums, which is a requirement of the affected site's R -3 -0 zone
(Multiple - Family Residential Ownership). Apartments are not permitted.
(2) General Plan Program 5.9.2.3. "Encourage that common open spaces
in multiple - family developments that are easily accessible to all residents."
The project's common, usable open space component, approximately 800
square feet, will be located in the rear portion of the site, which is
proximate to all four townhouse units. (3) General Plan Policy 2.2.
"Encourage infill development and recycling of land to provide adequate
residential sites." The development proposal is a good example of an infill
project; the intended site has been vacant for a number of years and the
adjoining properties support a large apartment complex, a small office
building and two single - family residences. (4) General Plan Program
1.3.1.5: "Encourage land uses consistent with the area's designation as
properties recycle." The proposed use, townhouse condominiums, is
permitted by right, according to the property's R -3- O zoning classification.
Further, the 4 -unit development falls within the density range of the site's
Medium Density Residential General Plan designation; moreover, the
proposed townhouses are consistent with the housing type that's
envisioned by the Medium Density Residential General Plan designation.
(5) General Plan Goal 8.2: "Maintain and enhance the appearance of
properties." The project site has been vacant for a number of years,
whereas project implementation will transform it into an multi - family
ownership development. (6) General Plan Policy 8.3.1: "Enhance the
views of propert y from public streets to exhibit a positive image." Project
implementation will enhance the view of the property for Imperial Highway,
a Major Arterial, drivers and pedestrians; the impact on Imperial traffic
cannot be understated, given that it carries about 33,000 vehicles daily.
2. That the proposed development is in accordance with the purposes and
objectives of this article and the zone in which the site is located. As
noted previously, the application and its accompanying project, a 4 -unit
townhouse condominium project, will cover an 11,948 square foot parcel.
The project site is zoned R -3 -0 and the intended use is "permitted by
right ", according to this zoning classification. Moreover, the project's
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 2
Resolution No. 15 - 2908
Planning Commission
development features, as well as its planned site improvements comply
with the applicable development standards; the only exceptions are the
building's rear and side yard setback distances and the height of the rear
portion of the building, variable building height requirement, which is
substandard due to the neighboring property's zoning classification: R1-
5,000. The R1 zone does not correspond with the property's General Plan
designation, nor does it reflect its improvements: 76 -unit apartment
complex. The appropriate zoning for the neighboring property is R -3 and
the zone variance requests would not be necessary with this classification.
3. That the proposed development's site plan and its design featuresh
including architecture and landscaping, will integrate harmoniously and
enhance the character and design of the site the immediate neighborhood
and the surrounding areas of the City. Contemporary is the design that
best describes the project's proposed architectural style. Renderings of
the buildings depict an attractive structure because of such features as its
design elements, emphasis on fagade articulation, use of contrasting, but
complementary building materials and the contemplated color palette. As
such, the development proposal will completely transform the character of
the site from a vacant lot to an attractive townhouse project. Similarly,
project implementation will have the same effect on the neighboring
properties. The project with its attractive features will have a positive
effect on neighboring properties, plus its design will not interfere with their
activities.
4. That the site plan and location of the buildings, parking areas, signs,
landscaping, luminaries and other site features indicate that proper
consideration has been given to both the functional aspects of the site
development, such as automobile and pedestrian circulation, and the
visual effects of the development from the view of the public streets. The
project site fronts on Imperial Highway, a Major Arterial Highway
according to the General Plan's Circulation Chapter. The front of the
building will face Imperial, while it will occupy the westerly part of the site,
with the driveway covering the easterly portion. According to project
renderings, the building is handsome, which will have a positive effect on
passing vehicular and pedestrian traffic. Moreover, the project's front
landscape setback represents a marked change, compared to its current
condition, which also will benefit passing vehicular and pedestrian traffic.
In addition, the proposed locations of the 4 -unit building, the guest parking
spaces, the drive approach and usable open space are well positioned,
and thus they'll work together.
5. That the proposed development will improve the community appearance
by preventing - extremes of dissimilarity or monotony in new construction or
in alterations of facilities. Project development will enhance the
appearance of the project environs. As a consequence, it will have a
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 3
Resolution No. 15 - 2908
Planning Commission
beneficial effect on neighboring land uses. On the other hand, its
proposed architectural style does not represent a dramatic departure from
the style employed by buildings that comprise the surrounding built
environment. Still, the contemplated design is unique, compared to
neighboring improvements because it is current and embodies today's
architectural trends.
6. That the site plan and design considerations shall tend to upgrade
property in the immediate neighborhood and surrounding_ areas with an
accompanying betterment of conditions affecting the public health, safety,
comfort, and welfare. Implementing the development proposal should
have a positive effect on the people inhabiting neighboring properties with
the transformation of a vacant lot into an active, 4 -unit townhouse
condominium development. Implementing the project will upgrade the site
and improve its appearance for those who come into contact with it;
namely, people who pass by when driving on Imperial Highway.
7. That the proposed development's site plan and its design features will
include graffiti- resistant features and materials in accordance with the
requirements of Section 4960 of Chapter 10 of Article IV of this code. The
conditions of approval for this entitlement, Site Plan Review PLN — 00175,
includes a condition stating the development's site plan and design
features will incorporate graffiti- resistant materials.
8. That the environmental impact of the proposed application has been
reviewed and determined to be exempt from the provisions of the
California Environmental Quality Act (CEQA), pursuant to CEQA Guideline
Section 15303 (Class 3 — New Construction or Conversion of Small
Structures), in that the development project falls within the parameters of
this section.
SECTION 3. Based upon the findings set forth in Sections 1 and 2 of this
resolution, the Planning Commission hereby approves Site Plan Review No.
PLN -14- 00175, subject to the Conditions of Approval attached hereto as Exhibit
A.
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 4
Resolution No. 15 - 2908
Planning Commission
SECTION 4. The Secretary shall certify the adoption of this Resolution.
PASSED, APPROVED AND ADOPTED this 18th day of March, 2015.
Hector Lu n, C Nrman
City Planning Commission
I HEREBY CERTIFY that the foregoing is a true copy of a Resolution adopted by
the Planning Commission of the City of Downey at a regular meeting thereof held
on the 18th day of March, 2015 by the following vote, to wit:
AYES;
ABSENT:
NOES:
ABSTAIN
COMMISSIONERS: Lujan, Flores, Rodriguez and Owens
COMMISSIONERS: Morales
COMMISSIONERS: None
COMMISSIONERS: None
Mary CaVanagh, Secretary(
City Planning Commission
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 5
Resolution No. 15 - 2908
Planning Commission
Exhibit A — Conditions of Approval
Site Plan Review Application PLN -14 - 00175
Planning Division
Site Plan Review PLN -14 -00175 is an application to develop a 4 -unit
townhouse condominium project with two (2) guest parking spaces on the
11,948 square foot lot at 8603 Imperial Highway, as shown on the approved
site plan filed with Planning Division staff on December 22, 2014.
Deviations or exceptions from the submitted plan shall not be permitted
without the approval of the City Planning Commission.
2. The Planning Commission shall retain jurisdiction to amend or add
conditions with a public notice and public hearing to assure compatibility
with the purpose and intent of the Comprehensive Zoning Ordinance and to
protect public health, safety and welfare.
3. All conditions of Site Plan Review PLN -14 -00175 shall be complied with
before this site plan review application becomes valid, unless otherwise
noted.
4. If City approval is contingent upon any changes to the application's plans as
submitted, the owner /applicant shall submit three (3) copies of the revised
plans, incorporating all approved amendments, overlays, modifications, etc.
to the Planning Division prior to the issuance of building permits.
5. The owner /applicant shall incorporate anti - graffiti elements into the
building's design, such as non - porous coatings on exterior wall surfaces,
plant materials, and anti - graffiti film on windows, subject to the approval of
the City Planner.
6. The owner /applicant agrees, as a condition of approval of this resolution, to
indemnify, defend and hold harmless, at applicant's expense, City and City's
agents, officers and employees from and against any claim, action, or
proceeding commenced within the time period provided in Government
Code Section 66499.37 to attack, review, set aside, void or annul the
approval of this resolution, to challenge the determination made by the City
under the California Environmental Quality Act or to challenge the
reasonableness, legality or validity of any condition attached hereto. City
shall promptly notify owner /applicant of any such claim, action or proceeding
to which City receives notice, and City will cooperate fully with applicant in
defense thereof. Owner /applicant shall reimburse the City for any court
costs and attorney's fees that the City may be required to pay as a result of
any such claim, action or proceeding. City may, in its sole discretion,
participate in the defense of any such claim, action or proceeding, but such
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 6
Resolution No. 15 - 2908
Planning Commission
participation shall not relieve the owner /applicant of the obligations of this
condition.
7. The owner /applicant shall make the following revisions to the building's
elevations:
• Building Colors. Apply colors that provide more contrast than what's
currently proposed.
• Roof Tiles. Apply a flat the with a color that is closer to the building's
ultimate color palette.
• Front Elevation — Stone Veneer. Apply stone veneer along the base
of the front elevation to match the stone accent that's planned for the
east elevation.
• Front Elevation Popouts. Eliminate the small gable that's planned for
the front elevation and replace it with the popouts that are planned for
the spaces above the garages. The popouts in the front will feature
the same gables that are shown above the garages, as well as the
same arch - shaped, recessed windows. Also, replace the two
rectangular- shaped windows in the center of the front elevation with
arch - shaped windows.
• Fascia. Paint the fascia the same dark brown color that's proposed
for the doors and window trim.
• Rear Elevation. Carry the same design features to the building's rear
elevation that are planned for the east elevation; adding shutters and
applying stacked stone along the base.
• Front Elevation Shutters. Apply the same style shutters that are
planned for the windows on the east elevation to the front elevation's
first -story windows.
8. Approval of Site Plan Review PLN — 14 — 00175 shall not be construed to
mean any waiver of applicable and appropriate zoning regulations, or any
Federal, State, County, and City laws and regulations. Unless otherwise
expressly specified, all other requirements of the City of Downey Municipal
Code shall apply.
9. Site Plan Review PLN — 14 — 00175 shall not become valid until and unless
the City Council accepts Final Tract Map No. 72992.
10. The applicant/owner shall provide irrigated landscape planters not less than
5 feet wide along the rear and side property lines in the rear yard setback,
as shown on the approved site plan, dated December 12, 2014. The
planters shall have trees and shrubs, not less than 6 feet high when planted,
which shall maintain a mature height of not less than 15 feet. At maturity
such landscaping shall form a solid screen.
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 7
Resolution No. 15 - 2908
Planning Commission
11. The applicant/owner shall pay Park In -Lieu fees of $1,008.11 per unit in
accordance with Sections 9231.8D and 9231.8E of the Downey Municipal
Code.
12. The applicant/owner shall install a rain gutter system along the entire edge
of the westerly roof line with accompanying downspouts and the runoff will
be directed to the project's underground infiltration system.
13. The applicant/owner shall install a commercial driveway approach, in
accordance with Drawing No. 20 from the Public Works Department of the
City of Downey.
Public Works
14. The owner /applicant hereby consents to the annexation of the property into
the Downey City Lighting Maintenance District in accordance with Division
15 of the Streets and Highways Code, and to incorporation or annexation
into a new or existing Benefit Assessment or Municipal Improvement District
in accordance with Division 10 and Division 12 of the Streets and Highways
Code and /or Division 2 of the Government Code of the State of California.
15. The owner /applicant shall install all utilities underground.
16. The facility design must provide refuse /recycle enclosure specifications
(location, size).
17. The owner /applicant shall be required to complete a construction &
demolition (C &D) waste management plan per Article V, Chapter 8 of the
Downey Municipal Code.
18. The owner /applicant shall submit an engineered grading plan and /or
hydraulic calculations and site drainage plan for the site (prepared and
sealed by a registered civil engineer in the State of California) for approval
by the Engineering Division and Building and Safety Division. All lot(s) shall
not have less than one (1 %) percent gradient on any asphalt or non -paved
surface, or less than one quarter (1/4 %) percent gradient on any concrete
surface. Provide the following information on plans: topographic site
information, including elevations, dimensions /location of existing /proposed
public improvements adjacent to project (i.e. street, sidewalk, parkway and
driveway widths, catch basins, pedestrian ramps); the width and location of
all existing and proposed easements; the location, depth and dimensions of
potable water, reclaimed water and sanitary sewer lines.
19. The owner /applicant shall construct/install curb, gutter, sidewalk, disabled
ramps, portland cement concrete driveway approaches, install (_1_) (24-
inch box with 2 -inch diameter trunk) street tree, and pavement along
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 8
Resolution No. 15 - 2908
Planning Commission
property frontage to the standards of the Department of Public Works.
Broken, uneven, or sub - standard curb, gutter, sidewalk, driveway, disabled
ramps and pavement, shall be replaced to the satisfaction of the Public
Works Department. Contact the Public Works Inspection Office at (562)
904 -7110 to have these areas identified just prior to initiating a grading plan,
The owner /applicant shall obtain all necessary plan approvals and permits
and shall provide that the standards of improvements, construction
materials, and methods of construction shall be in conformance with the
Standard Plans and Specification for Public Works Construction and as
modified by the City of Downey's Standard Plans and Specifications.
20. All driveway approaches shall be as wide as the driveway or parking aisle
they serve. All unused driveways shall be removed and reconstructed with
full- height curb, gutter and sidewalk.
21. The owner /applicant shall install pavement, which consists of a minimum
section of 4" thick aggregate base, and a minimum 2 -1/2" thick asphalt
concrete pavement.
22. The owner /applicant shall comply with the National Pollutant Discharge
Elimination System (NPDES) requirements of the Federal Clean Water Act;
the General Construction Activities Stormwater Permit (GCASP) of the State
Water Resources Control Board; and Ordinance 1142 of the Downey
Municipal Code (DMC). Furthermore, the owner /applicant shall provide and
be required to certify and append Public Works standard "Attachment A" to
all construction and grading plans as required by the LACoDPW Stormwater
Quality Management Plan (SQMP).
23. The owner /applicant shall install a sewer main and sewer lateral (to the front
property line) for each lot in the subdivision, and shall provide that the
design and improvements of sewers shall be to the standards of the City
Engineering Division. Septic systems are not acceptable.
24. The owner /applicant shall provide that all construction graffiti created as part
of this project in the public right -of- way to be removed.
25. The owner /applicant shall provide that no easements of any type be granted
over any portion of the subdivision to any agency, utility or organization
(private or public), except to the City of Downey prior to recordation of the
tract map. The owner /applicant shall grant easements in the name of the
City shall include:
• Vehicular easements
• Walkway easements
• Drainage easements
• Utility easements
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 9
Resolution No. 15 - 2908
Planning Commission
26. The owner /applicant shall submit a recorded Mylar copy of the final map, a
digital AutoCAD format file (AutoCAD 2012 or later) and scanned,
uncompressed TIFF images of final map on a portable media for city's GIS
system data updates and maintenance.
27. Install a common driveway approach in order to eliminate the curb hump
with the adjoining property to the east.
28. Provide sidewalk ADA accessibility.
29. Verify sewer main lateral connection possible conflict with the storm drain.
Utilities Division
30. The owner /applicant shall provide that the standards of improvements,
construction materials, and methods of construction shall be in conformance
with the Standard Plans and Specification for Public Works Construction
and as modified by the City of Downey's Standard Plans and Specifications.
31. The owner /applicant shall furnish and install a new (min. 1 -inch) dedicated
potable water service line, meter, and meter box for each unit.
32. The owner /applicant shall furnish and install a (min. 1 -inch) dedicated water
service line, meter, and meter box for the landscaping irrigation system.
33. The owner /applicant shall furnish and install backflow device(s) in
accordance with the Department of Public Works and the State and County
Department of Health Services requirements.
34. The owner /applicant shall confirm availability of adequate fire flow and
pressure in accordance with the Department of Public Works and Downey
Fire Department requirements.
35. The owner /applicant shall furnish and install the public potable water
improvements, including extension and /or replacement of existing mains
and associated facilities, necessary to provide adequate fire flow and
pressure to the site.
36. The owner /applicant shall furnish and install fire hydrant(s) and dedicated
fire protection lateral(s) including backflow devices, fire department
connections and other appurtenances as required by the Department of
Public Works and the Downey Fire Department. Such improvements may
include removal and /or replacement of existing fire hydrants, laterals,
backflow devices, and associated facilities with new facilities to current
Downey standards and materials. Backflow devices, fire department
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 10
Resolution No. 15 - 2908
Planning Commission
connections, and associated appurtenances are to be located on private
property and shall be readily accessible for emergency and inspection
purposes. Backflow devices shall be screened from street view by providing
sufficient landscaping to hide it.
37. The owner /applicant shall provide and record utility easement(s) for access
to, and inspection and maintenance of, public water lines, meters and
appurtenances, and backflow devices.
38. The owner /applicant shall furnish and install sanitary sewer lateral(s) and
associated facilities within the public right of way in accordance with the
requirements of the Department of Public Works.
39. The owner /applicant shall identify the point(s) of connection for the sanitary
sewer lateral(s) and confirm that sufficient capacity exists in the publicly
owned facilities in conformance with the requirements of the Department of
Public Works and the County Sanitation Districts of Los Angeles County
( CSDLAC).
40. The owner /applicant shall furnish and install the public sanitary sewer
improvements, including extension and /or replacement of existing mains
and associated facilities, necessary to provide adequate capacity for the site
as approved by the Department of Public Works and CSDLAC.
41. The owner /applicant is responsible for coordinating with and payment to the
City and CSDLAC for all sanitary sewer connection and capacity charges.
42. The owner /applicant shall obtain all necessary plan approvals and permits.
43. The owner /applicant shall provide improvement plan mylars, record drawing
mylars, and record drawing digital (AutoCAD — latest edition) files in
accordance with the requirements of the Department of Public Works that
have been signed by a civil engineer licensed in the State of California.
Final approval of new utilities shall be dependent upon submittal and
approval of record drawing mylars and scanned, uncompressed TIFF
images of record drawings on a CD /DVD -ROM media per City's GIS
Requirements.
44. Utility plans shall be submitted to and approved by the Department of Public
Works prior to the issuance of the grading plan permit
Building & Safety Division
45. A separate sewer shall be constructed to the building to the standards of the
City Engineering and Building & Safety Divisions or a sewer covenant shall
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 11
Resolution No. 15 - 2908
Planning Commission
be recorded with the Los Angeles County Recorder, and a copy filed with
the City Planning Division.
46. All electrical and telephone utilities shall be installed underground or at the
rear lot lines to the standards of the City Engineering and Building & Safety
Divisions.
47. Obtain all necessary plan approvals and permits.
48. Plans to be submitted through the Building & Safety Division shall comply
with the 2010 California Fire Code, 2010 California Building Code, current
Downey Municipal Code Ordinances and any other pertinent requirements
to be determined at time of plan submission and review.
Fire Department
49. The owner /applicant shall replace the fire hydrant in the parkway just east of
the project site with a new, commercial fire hydrant [DMC 3610(c)].
50. All residential units shall be equipped throughout with an automatic fire
sprinkler system in accordance with NFPA 13D and California Fire Code
Section 903.2.8.
51. All construction shall comply with fire separation requirements in
accordance with the California Building Code.
52. The owner /applicant/Developer shall comply with any additional fire code
requirements deemed necessary at the time of plan review and /or field
inspection.
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 12
Resolution No. 15 - 2908
Planning Commission
Attachment A
Storm Water Pollution Control Requirements for Construction Activities
Minimum Water Quality Protection Requirements for All Development
Construction Projects /Certification Statement
The following is intended as an attachment for construction and grading plans
and represent the minimum standards of good housekeeping which must be
implemented on all construction sites regardless of size.
❑ Eroded sediments and other pollutants must be retained on site and may
not be transported from the site via sheetflow, swales, area drains, natural
drainage courses or wind.
Stockpiles of earth and other construction related materials must be
protected from being transported from the site by the forces of wind or
water.
L: Fuels, oils, solvents and other toxic materials must be stored in
accordance with their listing and are not to contaminate the soil and
surface waters. All approved storage containers are to be protected from
the weather. Spills must be cleaned up immediately and disposed of in a
proper manner. Spills may not be washed into the drainage system.
❑ Non -storm water runoff from equipment and vehicle washing and any
other activity shall be contained at the project site.
❑ Excess or waste concrete may not be washed into the public way or any
other drainage system. Provisions shall be made to retain concrete wastes
on site until they can be disposed of as solid waste.
❑ Trash and construction related solid wastes must be deposited into a
covered receptacle to prevent contamination of rainwater and dispersal by
wind.
Sediments and other materials may not be tracked from the site by vehicle
traffic. The construction entrance roadways must be stabilized so as to
inhibit sediments from being deposited into the public way. Accidental
depositions must be swept up immediately and may not be washed down
by rain or other means.
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 13
Resolution No. 15 - 2908
Planning Commission
I'D Any slopes with disturbed soils or denuded of vegetation must be
stabilized so as to inhibit erosion by wind and water.
❑ Other
As the project owner or authorized agent of the owner, I have read and
understand the requirements listed above, necessary to control storm water
pollution from sediments, erosion, and construction materials, and I certify that I
will comply with these requirements.
Project Name:
Project Address:
Print Name
(Owner or authorized agent of the owner)
Signature Date
(Owner or authorized agent of the owner)
PLN -14 -00175 Site Plan Review — Grand Top LLC
Page 14